1.3 Water tank

Model
SXVD200LCJ/A-K
SXVD300LCJ/A-K
SXVD350LCJ/A-K
SXVD400LCJ/A-K
SXVD200LCJ2/A-K
SXVD300LCJ2/A-K
SXVD350LCJ2/A-K
SXVD400LCJ2/A-K
Notes:
(1) For specific provided capacity of water tank, please refer to the locat climate conditions
and suggestion of professional person.
(2) If specification is changed due to improvement of product, please subject to specific
name plate of product.

2. Basic Parameter of Unit

2.1 Performance parameter of outdoor unit

Model
Cooling capacity
kW
Heating capacity
kW
Noise
dB(A)
Water supply
temperature
Power source
Air volume
m
External static
Pa
pressure
Coolin
kW
g
Heatin
Rated
kW
g
power
Heatin
g
kW
water
Quantity of
set
compressor
Waterproof level
Liquid
mm
pipe
Air
Connecti
mm
pipe
ng pipe
High
pressu
mm
re air
GMV5 Home DC Inverter Multi VRF Units
Product code
ER20000160
ER20000180
ER20000230
ER20000220
ER20000170
ER20000190
ER20000200
ER20000210
GMV-S120
GMV-S140WL/
WL/A-S
12.10
14.00
55
220-240V~
220-240V~
50Hz/60HZ
50Hz/60HZ
3
/h
6000
0
3.05
3.3
3.3
1
IPX4
Φ9.52
Φ15.9
Φ12.7
Capacity of water
tank
(L)
200
300
350
400
200
300
350
400
GMV-S160WL/
A-S
A-S
14.00
16.00
16.50
18.50
56
58
50 (default), adjustable within 35~55℃
220-240V~
50Hz/60HZ
6300
6600
0
0
3.98
4.85
4.10
4.67
3.8
4.2
1
1
IPX4
IPX4
Φ9.52
Φ9.52
Φ15.9
Φ19.05
Φ12.7
Φ12.7
2
Outside view
GMV-S224W/
GMV-S280W/
A-X
A-X
22.4
28
25
31.5
57
58
380V-415V
380V-415V
3N ~
3N ~
50Hz/60Hz
50Hz/60Hz
14000
14000
80
80
5.35
7.7
5.8
7.6
5.0
5.2
1
1
IPX4
IPX4
Φ9.52
Φ9.52
Φ19.05
Φ22.2
Φ15.9
Φ15.9