Dosing tank volume
Metering pump
capacity
l
l / h
140
7.1
250
11.0
Degree of protection
Sound pressure level
16.2

Materials and properties of the components

Hydrazine metering system, 140 l
Back pressure, max.
bar
7.0
7.0
Protection against contact and moisture:
IP 65 in accordance with IEC 529, EN 60529, DIN VDE 0470 Part 1
The sound pressure level is < 70 dB (A)
According to DIN EN ISO 3743-1
1 - Metering pump Beta
BT4b0708NPE0000UA004100, capacity 7.1 l/h
®
at max. back pressure 7.0 bar. You can find more detailed information
in your operating instructions.
1 - Metering pump Beta
®
BT5b0420NPE0000UA004100, used as a
transfer pump, pump capacity 17.1 l/h at max. back pressure 4 bar.
You can find more detailed information in your operating instructions.
1 - PE dosing tank, volume 140 l, with litre scale and closable screw lid,
"gas-tight version"
1 - Complete PVC suction assembly, "gas-tight version" (installed in the
dosing tank)
1 - Electrical level switch with support pipe (installed in the dosing tank)
1 - PVC manual stirrer, "gas-tight version"
1 - Fastening plate for mounting the metering pumps on the storage tank
1 - Metering vessel, transparent PVC, volume 2 l, with electrical level
switch for switching off the transfer pump on reaching a high level, as
well as the necessary hoses
1 - Active carbon filter
1 - PVC ball valve, d16, NW10 with pipework
1 - 1.4571 stainless steel injection valve , connector 8 mm-1/2"
1 - Metering line PTFE , 11 bar, 12 x 9 mm
1 - Micro-Matic coupling with flushing adapter (optional)
1 - Suction line PVC 12 x 9 mm, 1.5 m
1 - Vapour recovery line PVC 8 x 5 mm, 1.5 m
Transfer pump capacity
l / h
approx. 17
approx. 32
Technical data
Order no.
913018
913019