February 2019
6
Verify operation
There are four methods available to verify operation:
•
Using the optional local display (LCD)
•
Using the Field Communicator
•
Using the Wireless Gateway's integrated web interface
•
Using AMS Suite Wireless Configurator
If the device was configured with the Network ID and Join Key, and sufficient
time has passed, the transmitter will be connected to the network.
6.1
Local display (LCD display)
The LCD display will show the output values based on the wireless update
rate. Refer to the Rosemount 3051S and 3051SMV Wireless manuals for error
codes and other LCD display messages..
Procedure
Press and hold the Diagnostic button for at least five seconds to display the
TAG, Device ID, Network ID, Network Join Status, and Device Status screens.
Searching for
network
N E T w K
S R C H N G
6.2
Field Communicator
For HART Wireless transmitter communication, an appropriate DD is required.
For connecting with a Field Communicator, refer to
connections.
Function
Communications
Quick Start Guide
Joining network
n e t w k
N E G O T
Fast Key
sequence
3, 4
Connected with
limited bandwidth
n e t w k
L I M - O P
Field Communicator
Menu Items
Join Status, Wireless Mode, Join Mode, Number of
Available Neighbors, Number of Advertisements
Heard, Number of Join Attempts
Quick Start Guide
Connected
n e t w k
O K
21