Download Print this page

Emerson Rosemount 2051 Series Quick Start Manual page 28

Pressure transmitter and flowmeter with profibus pa protocol
Hide thumbs Also See for Rosemount 2051 Series:

Advertisement

Quick Start Guide
7.3.3 International
E7 IECEx Flameproof
Certificate IECExKEM08.0024X
Standards IEC 60079-0:2011, IEC 60079-1:2014-06, IEC
Markings
Table 7-4: Process Connection Temperature
Temperature class
T6
T5
T4
Special Conditions for Safe Use (X):
1. The device contains a thin wall diaphragm less than 1 mm thickness
that forms a boundary between zone 0 (process connection) and zone
1 (all other parts of the equipment). The model code and datasheet
are to be consulted for details of the diaphragm material. Installation,
maintenance and use shall take into account the environmental
conditions to which the diaphragm shall be subjected. The
manufacturer's instructions for installation and maintenance shall be
followed in detail to assure safety during its expected lifetime.
2. Appropriate cable, glands and plugs need to be suitable for a
temperature of 5°C greater than maximum specified temperature for
location where installed.
3. Flameproof joints are not intended for repair.
4. Non-standard paint options may cause risk from electrostatic
discharge. Avoid installations that could cause electrostatic build-up
on painted surfaces, and only clean the painted surfaces with a damp
cloth. If paint is ordered through a special option code, contact the
manufacturer for more information.
I7 IECEx Intrinsic Safety
Certificate
Standards
Markings
28 Rosemount 2051 Pressure Transmitter and Rosemount 2051CF Series Flowmeter Quick Start Guide
60079-26:2014-10
Ex db IIC T6...T4 Ga/Gb T6(-60 °C ≤ T
T
≤ +80 °C)
a
Process
temperature
-60 °C to +70 °C
-60 °C to +80 °C
-60 °C to +120 °C
IECEx BAS 08.0045X
IEC60079-0:2011, IEC60079-11:2011
Ex ia IIC T4 Ga (-60 °C ≤ T
≤ +70 °C), T4/T5(-60 °C ≤
a
Ambient
temperature
-60 °C to +70 °C
-60 °C to +80 °C
-60 °C to +80 °C
≤ +70 °C)
a
February 2019

Advertisement

loading

This manual is also suitable for:

Rosemount 2051cf series