Conditions Of Installation; Fireplace Surround & Suitability - Flavel Orchestra Installation And Maintenance Instructions Manual

Coal effect balanced flue gas fire
Table of Contents

Advertisement

INSTALLATION REQUIREMENTS
1.1

CONDITIONS OF INSTALLATION

In Great Britain :-
It is the law that all gas appliances are installed only by a CORGI Registered
Installer, in accordance with these installation instructions and the Gas Safety
(Installation and Use) Regulations 1998 as amended. Failure to install appliances
correctly could lead to prosecution. It is in your own interest and that of safety to
comply with the law.
The installation must also be in accordance with all relevant parts of the Local and
National Building Regulations where appropriate, the Building Regulations
(Scotland Consolidation) issued by the Scottish Development Department, and all
applicable requirements of the following British Standard Code of Practice.
1. B.S. 5871 Part 3 Installation of Decorative Fuel Effect Gas Fires
2. B.S. 6891 Installation of Gas Pipework
3. B.S. 5440 Parts 1 & 2 Installation of Flues and Ventilation
4. I.S. 813 : 1996 Domestic Gas Installation (Republic of Ireland)
In Republic of Ireland :-
No purpose made additional ventilation is normally required for this appli-
ance, when installed in G.B. When Installing in I.E. please consult document
I.S. 813 : 1996 Domestic Gas Installation, which is issued by the National
Standards Authority of Ireland. If installing in Northern Ireland, please
consult local building regulations. Any purpose made ventilation must be
checked periodically to ensure that it is free from obstruction.
1.2
FIREPLACE / SURROUND SUITABILITY
The fire must only be installed on a hearth it must not be installed directly onto
carpet or other combustible floor materials.
The fire is suitable for fitting to non-combustible fire place surrounds and propri-
etary fire place surrounds with a temperature rating of at least 150 o c.
If a heating appliance is fitted directly against a wall without the use of a fire
surround or fire place all combustible material must be removed from behind
the trim. Soft wall coverings such as blown vinyl, wall paper etc. could be
affected by the rising hot air and scorching and/or discoloration may result.
Due consideration should be made to this when installing or decorating.
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fbfn76gFbfn98gFbfp76gFbfp98gOrchestra fbfn g seriesOrchestra fbfn76g ... Show all

Table of Contents