Model 5065A
Circuit Diagrams, Theory, and Maintenance
Figure 7-14. Top Operating Controls
• ~ >
k
1.
Synthesizer T I M E C L O C K
SELECTOR
t h u m b ­
wheel s w i t c h : selects synthesized frequency
2
Synthesizer
T I M E
SCALE
SELECTOR
H l - L O
switch:
used w i t h thumbwheel switch to select
synthesized frequency.
3
C L O C K SET STOP switch
(Option 001 only).
digital clock is stopped when switch is depressed.
starts when released.
4
C L O C K
SET FAST switch
(Option 001 only)
digital clock second hand is accelerated when
switch is depressed, resumes normal operation
when released
5
Clock
SYNC switch (Option 001 only)
Syn­
chronizes digital clock with an external
clock
when
depressed: clock
remains
synchronized
wnen released
Clock TIME DELAY thumbwheel switch (Option
001 only)
selects time delay between an ex­
ternal reference pulse and the internal 1 pulse-
per-second clock pulse
Adjustable in decade
steps from 1 ps to 1 sec.
0-1
USEC
TIME DELAY c o n t r o l (Option 001
only)
Allows c o n t i n u o u s adjustment of
clock
pulse delay over any 1 /jsec range
Battery fuse
removed momentarily to d i s c o n ­
nect optional standby battery from circuit
for
storage or shipment
Battery will remain dis­
c o n n e c t e d after fuse is replaced