SHORT PRESS:
By pressing this key, you open the lid of the centrifuge. When the lid opens,
the key light turns off. When closing the lid, press it down with your hands,
(LID)
until it locks up. When the lid is closed, the key lights up.
The key light turns off during the run of the centrifuge and thus indicates that
you can't open the lid during the run.
LONG PRESS:
By pressing and holding this key, you set the lid latch to initial position. This is
needed in case of power failure during the opening of the lid, when lid latch
motor stops in undefined position. When power returns, it could happen that
you can't open or close the lid. If this happens, press the key for approximately
two seconds, until you hear the sound of lid latch motor, then release it. After
that, you will be able to open and close the lid normally.
SHORT PRESS:
By pressing this key, you start the run of the centrifuge. The key lights up and
thus indicates that the centrifuge is running.
(START)
At the end of the set running time or manual stopping of the centrifuge, the
braking procedure of the rotor is activated and the centrifuge stops. The next
run is possible, when the rotor stops completely.
LONG PRESS:
By pressing and holding this key, you perform the fast spin. The centrifuge
runs for as long as you hold the key pressed. Time of run in seconds is
displayed on time display. The acceleration and braking levels are fixed to 9
(the highest), and they can't be changed. When you release the key, the
braking procedure of the rotor is activated and the centrifuge stops.
By pressing this key, you stop the run of the centrifuge. The key lights up and
thus indicates that the centrifuge is stopping. The braking procedure of the
rotor is activated and the centrifuge stops. Until the centrifuge stops
(STOP)
completely, the START key remains lit, thus indicating that the rotor is still
turning.

3.3 TURNING ON THE CENTRIFUGE

Use the enclosed power cord to connect the centrifuge to the mains power supply.
Turn on the main switch, which is located on the front of the right side of the centrifuge.
All segments (eights) are displayed on all displays at first, and all the keys and indicators light up
simultaneously. Then centrifuge model (C-30R) and program version (X.XX) are displayed, then
lines, and finally the values of operation parameters are displayed.
The values of operation parameters (temperature, rotational speed, centrifugal force, run time,
acceleration and braking level) are automatically set to the last used values.