Alarm
Number
code
of
(MDI)
flashes
AL 91
2
AL93
0
AL94
6
AL95
7
AL96
0
AL97
5
AL98
0
AL99
6
28
Operating and maintenance instructions - COMPACT 8, 8W, 10N, 10, 12
Message on
console
Incorrect configuration of
the "Standard" and
"Europe" software
VERSION NOT
versions.
OK
The "version" and "ok for
version" parameters are dif-
ferent.
WRONG
The platform console's
INPUT
ENABLE starting switch is
CONF.
closed while a movement
is requested from the chas-
sis control panel.
MICRO
The Siemens calcula-
CONTROL
tor does not respond
KO
correctly.
PRESSURE
Pressure sensor alarm.
NOT OK
HEIGHT 8
Maximum height reached.
METERS
CURR.
Current out of control.
PROTEC-
TION
The hour shown on the
MDI and the chopper differ.
CHECK UP
The 'Check up' func-
NEEDED
tion has been activated.
Description
Solution
Set the two parameters:
- to 2 to activate weighing.
- to 1 to configure weighing
from the bottom station.
• Replace the chassis control
panel's lift switch.
• Replace the chopper.
• Check:
- the continuity of the cable
bundle between the weighing
card and the variator.
• Check input 36.
• Replace the chopper.
• Wait for 6 minutes after putting
into service.
• If the problem remains, connect
the console instead of the MDI.
• In this configuration, if the ma-
chine functions again, MDI fault.
• If the machine still does not
function, defective bundle or
chopper.
• Deactivate the 'CHECK UP
ENABLE' function using the
console.