1
3
2
Photo 1
Photo 2
Alarm
Number
code
of
(MDI)
flashes
0 +
-
Red
Diode
AL01
3
AL06
6
AL10
2
AL13
6
26
Operating and maintenance instructions - COMPACT 8, 8W, 10N, 10, 12
3.2.2.1 -State of charge of the batteries
The state of charge of the battery is indicated by 5 LEDs:
• When the battery is correctly charged, four green LEDs are on. (item 1 Photo
1)
• When the battery discharges itself, the LEDs go out one by one.
• When the battery is discharged, the red LED (item 2, Photo 1) comes on, rai-
sing is cut but travel remains possible.
• It is compulsory to recharge the batteries otherwise they would be excessi-
vely discharged and damaged.
3.2.2.2 -Hour counter
The hours are counted on the screen (item 3, Photo 1) when the electric pump
unit is operating. At that time the " timer " flashes.
3.2.2.3 -Resetting
This takes place when the battery is correctly recharged
3.2.2.4 -Alarm : Problem on the machine
When there is a problem on the machine
• the operator on the platform is warned by flashes (see Photo 2). The pro-
blem can be identified from the number of flashes (see table below).
• the operator on the ground is warned by a numerical indication. The problem
can be identified from the number displayed on the hour counter's screen
(see table below).
Message on
console
BATTERY
•
Batteries
LOW
otherwise:
•
Faulty chopper.
EVP NOT OK
•
Defective coil or YV7/
YV9 coil's supply.
SERIAL
•
Incorrect or lack of
ERROR #1
reception of serial card's
signal to chopper.
WEIGHING
Problem on the weighing
CARD KO
card
EEPROM KO
•
Fault in the chopper's
EEPROM.
Description
discharged,
•
resetting the emergency stop or
changing station with the key selec-
tor. See Chap. 4.4.2, page 37.
Solution
• Check:
- the batteries
- the charger
- the electric circuit's supply.
• Otherwise, replace the chopper.
• Look for failure on the lifting
cylinders' lowering coil(s).
• Look for failure on:
- the platform console's serial
card;
- the bundle;
- the connections between the
platform's console and the
chopper.
• Other possible reason: incorrect
cabling on the MDI line or the
MDI display.
Leave at least 2 seconds before
• Replace the chopper.