Alarm
Number
code
of
(MDI)
flashes
AL32
3
AL37
4
AL38
4
AL49
5
AL53
5
AL60
3
AL62
9
AL73
1
AL74
4
AL75
4
AL78
2
AL79
2
AL80
2
AL90
4
Message on
console
VMN NOT OK
Low VMN at rest or
inconsistent with the
applied VMN at work.
CONTAC-
SB1's contact stuck.
TOR
CLOSED
CONTAC-
SB1's auxiliary contact
TOR OPEN
faulty.
I=O EVER
Null current on
movement request.
STBY I HIGH
High current at rest.
CAPACITOR
Capacitors do not
CHARGE
charge on starting the ma-
chine.
TH.
Chopper's thermal
PROTEC-
protection:
TION
over 75°C/167F
POWER
Short circuit on an
FAILURE
electrovalve's coil or the
horn or SB1's coil.
DRIVER
SB1 conctactor's driver
SHORTED
faulty or in short circuit.
CONTAC-
SB1 conctactor's driver
TOR DRIVER
malfunctioning or will not
close.
VACC NOT
Manipulator at rest.
OK
INCORRECT
Incorrect starting
START
sequence.
FORW+BAC
Backward and forward
K
movements requested si-
multaneously.
DRIVER 1 KO
YV6 coil in short circuit.
Description
temperature
Solution
• Check the chopper's isolation
between B- and P terminals.
• If the value is below 65 KOhms,
replace the chopper.
• Otherwise replace the motor.
• Check SB1.
• Check SB1.
• Replace the chopper.
• Replace the chopper.
• Replace the chopper.
• Replace the chopper.
• Check:
- the
electrovalves'
coils,
- the horn;
- SB1 contactor's coil.
• Defective SB1 or chopper.
• Defective SB1 or chopper.
• Check the joystick's output vol-
tage using the console's
TESTER mode.
• In the case of an incorrect pro-
graming, adjust the values
calibrating the serial card.
• Otherwise replace the chopper.
• Check the joystick's output data
using the console's TESTER
mode, then replace either the
joystick or the chopper,
according to the tests' results.
• Check the joystick's output data
using the console's TESTER
mode, then replace either the
joystick or the chopper,
according to the tests' results.
• Check YV6 electrovalve's coil