Advertisement

Quick Links

páãìä~íáçå=råáí=`UH=`~ÄáåÉí=p
léÉê~íáåÖ=fåëíêìÅíáçåë
båÖäáëÜ

Advertisement

Table of Contents
loading

Summary of Contents for Sirona C8+ Cabinet S

  • Page 1 páãìä~íáçå=råáí=`UH=`~ÄáåÉí=p léÉê~íáåÖ=fåëíêìÅíáçåë båÖäáëÜ...
  • Page 2 Sirona Dental Systems GmbH Dear customer, thank you for purchasing a Simulation Unit C8+ Cabinet S unit from Sirona. The technical documentation supplied is also part of the product. You should always keep this documentation within reach. These Operating Instructions describe your simulation workstation with the maximum range of equipment possible.
  • Page 3: Table Of Contents

    Sirona Dental Systems GmbH Table of contents Table of contents Explanation of the symbols used ..................Warning and safety information ..................Technical description ......................Operating and functional elements ................... System overview ............................. Main switch ..............................Control on the dentist element ........................
  • Page 4 Table of contents Sirona Dental Systems GmbH 64 72 695 D3625 D3625.201.01.03.02...
  • Page 5: Explanation Of The Symbols Used

    Sirona Dental Systems GmbH 1 Explanation of the symbols used Operating Instructions Simulation Unit C8+ Cabinet S Explanation of the symbols used Symbol Explanation Symbol Explanation Can be sterilized in the autoclave 273,2 °F 134 °C at 134°C/273.2°F Can be thermodisinfected in the 93 °C 199,4 °F...
  • Page 6: Warning And Safety Information

    Sirona Dental Systems GmbH Operating Instructions Simulation Unit C8+ Cabinet S Warning and safety information Intended use This Simulation Unit C8+ Cabinet S is used for training purposes. It is a laboratory workstation that may not be used to treat living persons! This unit is not intended for operation in areas subject to explosion hazards.
  • Page 7 Sirona Dental Systems GmbH 2 Warning and safety information Warning and safety information Operating Instructions Simulation Unit C8+ Cabinet S Warning and safety information Water quality compliance A safety unit as specified by EN1717/DIN 1988 must be installed on site.
  • Page 8 2 Warning and safety information Warning and safety information Sirona Dental Systems GmbH Operating Instructions Simulation Unit C8+ Cabinet S Warning and safety information On the basis of the Directive 2012/19/EU and the country-specific disposal Disposal regulations on waste electrical and electronic equipment, we would like to stress that such equipment must be disposed of accordingly within the European Union (EU).
  • Page 9: Technical Description

    Sirona Dental Systems GmbH 3 Technical description Warning and safety information Operating Instructions Simulation Unit C8+ Cabinet S Technical description Simulation Unit C8+ Cabinet S Model designation 230 V AC±10 % 50 / 60 Hz Power connection 1.5 A at 230 VAC Nominal current T 10 A H, 250 V AC, Order No.
  • Page 10 3 Technical description Warning and safety information Sirona Dental Systems GmbH Operating Instructions Simulation Unit C8+ Cabinet S Ordinary equipment (without protection against ingress of water) Degree of protection against ingress of water The foot control has IP X1 degree of protection against liquids (drip-proof) Intermittent operation for electric motor in- 1 min.
  • Page 11: Operating And Functional Elements

    Sirona Dental Systems GmbH 4 Operating and functional elements Warning and safety information Operating Instructions Simulation Unit C8+ Cabinet S 4.1 System overview Operating and functional elements System overview Main switch SPRAYVIT Main fuse Electric motor Operating elements on the dentist element...
  • Page 12: Main Switch

    4 Operating and functional elements Operating and functional elements Sirona Dental Systems GmbH 4.2 Main switch Operating Instructions Simulation Unit C8+ Cabinet S Operating and functional elements Main switch Switch the main switch ON( I ). The green control LED (A) on the dentist element lights up.
  • Page 13: Control On The Dentist Element

    Sirona Dental Systems GmbH 4 Operating and functional elements Operating and functional elements Operating Instructions Simulation Unit C8+ Cabinet S 4.3 Control on the dentist element Control on the dentist element A = Speed control motor / SIROSONIC L intensity...
  • Page 14: Configure For Highspeed Handpiece

    4 Operating and functional elements Operating and functional elements Sirona Dental Systems GmbH 4.4 Configure for highspeed handpiece Operating Instructions Simulation Unit C8+ Cabinet S Configure for highspeed handpiece A = Configured to motor B = Remove motor hose and attach high- speed handpiece hose Remove the highspeed handpiece.
  • Page 15: Configure For Motor

    Sirona Dental Systems GmbH 4 Operating and functional elements Operating and functional elements Operating Instructions Simulation Unit C8+ Cabinet S 4.5 Configure for motor Configure for motor A = Configured for highspeed handpiece B = Remove highspeed handpiece hose and attach motor hose Remove motor C = Hold down >...
  • Page 16: Control Panel On The Dentist Element - Motor Clockwise/Counterclockwise Rotation

    4 Operating and functional elements Operating and functional elements Sirona Dental Systems GmbH 4.6 Control panel on the dentist element - MOTOR CLOCKWISE/COUNTERCLOCKWISE ROTATION Operating Instructions Simulation Control panel on the dentist element - MOTOR CLOCKWISE/COUNTER- CLOCKWISE ROTATION Press button >...
  • Page 17: Putting The System Into Operation

    Sirona Dental Systems GmbH 5 Putting the system into operation Operating and functional elements Operating Instructions Simulation Unit C8+ Cabinet S 5.1 Starting an instrument Putting the system into operation Starting an instrument NOTE Use only treatment instruments approved by Sirona! Also observe the operating instructions of the treatment instruments.
  • Page 18: Adjusting The Driving Air Pressure

    5 Putting the system into operation Operating and functional elements Sirona Dental Systems GmbH 5.2 Adjusting the driving air pressure Operating Instructions Simulation Unit C8+ Cabinet S Adjusting the driving air pressure Only by a service engineer Instrument spray ON/OFF – chip blower...
  • Page 19: Instruments - Adjusting The Spray Intensity

    Sirona Dental Systems GmbH 5 Putting the system into operation Operating and functional elements Operating Instructions Simulation Unit C8+ Cabinet S 5.4 Instruments – adjusting the spray intensity Instruments – adjusting the spray intensity A = Spray WATER Spray air only by...
  • Page 20: Dentist Element Options

    6 Dentist element options Operating and functional elements Sirona Dental Systems GmbH 6.1 SPRAYVIT 3-way syringe Operating Instructions Simulation Unit C8+ Cabinet S Dentist element options SPRAYVIT 3-way syringe Click Check 64 72 695 D3625 D3625.201.01.03.02...
  • Page 21: Dci 3-Way Syringe

    Sirona Dental Systems GmbH 6 Dentist element options Operating and functional elements Operating Instructions Simulation Unit C8+ Cabinet S 6.2 DCI 3-way syringe DCI 3-way syringe 3 min Check 64 72 695 D3625 D3625.201.01.03.02...
  • Page 22: Electric Motor

    6 Dentist element options Operating and functional elements Sirona Dental Systems GmbH 6.3 Electric motor Operating Instructions Simulation Unit C8+ Cabinet S Electric motor Use only Sirona electric motors! Speed in % Diode/display 1 - 4 5 - 14 15 - 24...
  • Page 23: Sirosonic L Scaler

    Sirona Dental Systems GmbH 6 Dentist element options Operating and functional elements Operating Instructions Simulation Unit C8+ Cabinet S 6.4 SIROSONIC L scaler SIROSONIC L scaler NOTE Not available in the USA! Power in % Diode/display Wrong 1 - 4...
  • Page 24: Sirosonic L Endodontic Scaler

    6 Dentist element options Operating and functional elements Sirona Dental Systems GmbH 6.5 SIROSONIC L endodontic scaler Operating Instructions Simulation Unit C8+ Cabinet S SIROSONIC L endodontic scaler NOTE Not available in the USA! In endodontics mode, the maximum inten- sity of the ultrasonic handpiece is restricted to ensure safe operation.
  • Page 25: Care And Cleaning

    Sirona Dental Systems GmbH 7 Care and cleaning Operating and functional elements Operating Instructions Simulation Unit C8+ Cabinet S 7.1 Wipe disinfection Care and cleaning Wipe disinfection ATTENTION Use only cleaning agents ap- proved by SIRONA! Wipe disinfection Care and cleaning agents...
  • Page 26: Sprayvit 3-Way Syringe

    7 Care and cleaning Operating and functional elements Sirona Dental Systems GmbH 7.3 SPRAYVIT 3-way syringe Operating Instructions Simulation Unit C8+ Cabinet S SPRAYVIT 3-way syringe 3 min 64 72 695 D3625 D3625.201.01.03.02...
  • Page 28 tÉ=êÉëÉêîÉ=íÜÉ=êáÖÜí=íç=ã~âÉ=~åó=~äíÉê~íáçåë=ïÜáÅÜ=ã~ó=ÄÉ=êÉèìáêÉÇ=ÇìÉ=íç=íÉÅÜåáÅ~ä=áãéêçîÉãÉåíëK «=páêçå~=aÉåí~ä=póëíÉãë=dãÄe=OMNS i~åÖì~ÖÉW=ÉåÖäáëÜ= mêáåíÉÇ=áå=dÉêã~åó aPSORKOMNKMNKMPKMO===MTKOMNS ûKJkêKW= NOO=RNP fãéêáã¨=Éå=^ääÉã~ÖåÉ páêçå~=aÉåí~ä=póëíÉãë=dãÄe áå=íÜÉ=rp^W SQ=TO=SVR=aPSOR c~Äêáâëíê~≈É=PN páêçå~=aÉåí~ä=póëíÉãë=ii` lêÇÉê=kç SQSOR=_ÉåëÜÉáã QUPR=páêçå~=aêáîÉI=pìáíÉ=NMM dÉêã~åó `Ü~êäçííÉI=k`=OUOTP ïïïKëáêçå~KÅçã...

Table of Contents