General information Sirona Dental Systems GmbH Installation Requirements General information About this document This document describes the installation requirements for the C8 dental treatment centers. Their subsequent installation is described in the Installation Instructions: • REF 59 42 912 (C8 •...
Page 3
Sirona Dental Systems GmbH List of Contents Installation Requirements C8 List of Contents Preparations.......................... Safety......................Media quality....................Supply lines in the termination panel ............Underfloor installation of SIVISION connections ......... Mounting plates for C8 (not for C8 Turn)........... Demonstration plate for C8 Turn..............
Sirona Dental Systems GmbH 1 Preparations Installation Requirements C8 1.2 Media quality Suction machine oil-free >80 µm Cold water (drinking water quality) Dilution hardness Water quality Air quality Lime deposits and corrosion residues in tap water can lead Oil-free, dry and hygienically perfect air is required for driv-...
1 Preparations Sirona Dental Systems GmbH Installation Requirements C8 1.3 Supply lines in the termination panel Center base plate opening to floor Foot end 7, 6 3/8" min. 500mm max. max. max. 20" 60mm 3/16" 2 3/8" 3/16" 60 28 000 D3417...
Page 9
36.5mm!) recommend using an installation template. They can Water drain DN40 HT-PP DIN 19560 (polypro- be ordered from Sirona under REF 33 15 830. pylene, inner diameter 36.5mm!) If necessary, you can also prepare the template your- Installation pipe, DN40 HT-PP DIN 19560 self based on the above sketch (not true to scale!).
Page 10
1 Preparations Sirona Dental Systems GmbH Installation Requirements C8 Supply lines in the termination panel 3 / 8 “ , 5 m Ø 3 6 < 6 < 2 8 “ Ø < 5 m 6 “ < 3 / 1 “...
Sirona Dental Systems GmbH 1 Preparations Installation Requirements C8 1.4 Underfloor installation of SIVISION connections SIVISION L15, L37, L38, Audio protective ground wire Important information for the installer Pull cables L15, L37 and L38 as well as the audio ca-...
1 Preparations Sirona Dental Systems GmbH Installation Requirements C8 1.5 Mounting plates for C8 (not for C8 Turn) Chair plate REF 58 26 511 For especially uneven floor conditions, a steel chair plate is available to compensate for the irregularities of the floor (REF 58 26 511).
Sirona Dental Systems GmbH 1 Preparations Installation Requirements C8 1.6 Demonstration plate for C8 Turn Demonstration plate Turn REF 59 46 269 For floors which do not permit permanent con- nection of the unit (e.g. demo operation at a fair), installation on a steel demo plate is possible (REF 59 46 269).
1 Preparations Sirona Dental Systems GmbH Installation Requirements C8 1.7 C8 Dentist element Rear delivery / Side delivery ATTENTION In order to ensure mechanical stability, in- stall the dentist element only on cabinets ap- proved by Sirona. Never place any objects on the dentist ele- ment.
2 Dimensions, technical data Sirona Dental Systems GmbH 2.1 C8 1:20 Installation Requirements C8 2.1 C8 1:20 Recommended distances from cabinet or wall. 1300 1700 51 3/16” 67” 2500 98 7/16” Hazard warning: The here mounted lamp and the dentist...
Page 17
Sirona Dental Systems GmbH 2 Dimensions, technical data Installation Requirements C8 2.1 C8 1:20 1:20 With long support arm for the dentist element LEDview SIROLUX 10° Height of lamp with SIVISION on swivel arm or lamp support tube 3 1/2”...
Page 19
Sirona Dental Systems GmbH 2 Dimensions, technical data Installation Requirements C8 2.1 C8 1:20 1:20 With short support arm for the dentist element LEDview SIROLUX 10° Height of lamp with SIVISION on swivel arm or lamp support tube 1950 3 1/2”...
Sirona Dental Systems GmbH 2 Dimensions, technical data Installation Requirements C8 2.4 C8 Side delivery 1:20 2.4 C8 Side delivery 1:20 LEDview SIROLUX 10° 3 1/2” Height of lamp with 65° SIVISION on swivel arm or lamp support tube 1950 45°...
Sirona Dental Systems GmbH 2 Dimensions, technical data Installation Requirements C8 2.5 C8 : Technical data 2.5 C8 : Technical data Dimensions of the packaging Dentist element, assistant element 120cm x 63cm x 110cm C8+ Cart Dentist element 97,5cm x 50,5cm x 50,5cm...
2 Dimensions, technical data Sirona Dental Systems GmbH 2.6 C8 Turn 1:20 Installation Requirements C8 2.6 C8 Turn 1:20 Recommended distances from cabinet or wall. 1600 1600 63” 63” 2500 98 7/16” Hazard warning: The here mounted lamp and the den-...
Page 29
Sirona Dental Systems GmbH 2 Dimensions, technical data Installation Requirements C8 2.6 C8 Turn 1:20 Turn 1:20 Minimum clearances for conversion of treatment center from right-handed to left-handed version an vice versa 2700x2650mm 1050 1050 41 3/8” 41 3/8” 1600 1600 63”...
Page 30
2 Dimensions, technical data Sirona Dental Systems GmbH 2.6 C8 Turn 1:20 Installation Requirements C8 Turn 1:20 Minimum clearances for conversion of treatment center from right-handed to left-handed version an vice versa 3650x2100mm 1050 1050 41 3/8” 41 3/8” Storage space max.
Page 31
Sirona Dental Systems GmbH 2 Dimensions, technical data C8 1:20 Installation Requirements C8 2.6 C8 Turn 1:20 Turn 1:20 Equal working conditions for right-handers and left-handers: Position for right-handers 1050 1050 41 3/8” 41 3/8” 1600 1600 63” 63” 1234 48 1/2”...
Page 32
2 Dimensions, technical data C8 1:20 Sirona Dental Systems GmbH 2.6 C8 Turn 1:20 Installation Requirements C8 Turn 1:20 Equal working conditions for right-handers and left-handers: Position for left-handers 1050 1050 41 3/8” 41 3/8” 1600 1600 63” 63” 1234 48 1/2”...
Page 33
Sirona Dental Systems GmbH 2 Dimensions, technical data C8 1:20 Installation Requirements C8 2.6 C8 Turn 1:20 Turn 1:20 LEDview SIROLUX 10° Height of lamp with SIVISION on swivel arm or lamp support 8 1/4” tube 1950 65° 76 3/4”...
Sirona Dental Systems GmbH 2 Dimensions, technical data C8 1:20 Installation Requirements C8 2.9 C8 Turn: Technical data 2.9 C8 Turn: Technical data Dimensions of the packaging Dentist element, assistant element 120cm x 63cm x 110cm Cart Dentist element 97,5cm x 50,5cm x 50,5cm...
Electromagnetic compatibility 3.1 Accessories ........................... 3.2 Electromagnetic emission ...................... 3.3 Immunity to interference ......................3.4 Working clearances ....................... NOTE The C8 fulfills all requirements for electromagnetic compatibility (EMC) compliant with IEC 60601-1-2. The C8 is referred to as "UNIT" in the following. Observance of the following information is necessary to ensure safe operation regarding EMC aspects.
2nd protective ground wire, 2.5mm , 10m Sirona • The UNIT may be operated only with accessories and spare parts approved by Sirona. Unapproved accesso- ries and spare parts may lead to an increased emission of or a reduced immunity to interference. •...
Sirona Dental Systems GmbH 3 Electromagnetic compatibility Installation Requirements C8 3.2 Electromagnetic emission The UNIT is intended for operation in the electromagnetic The customer or user of the UNIT should make sure that it environment specified below. is used in such an environment.
3 Electromagnetic compatibility Sirona Dental Systems GmbH Installation Requirements C8 3.3 Immunity to interference The UNIT is intended for operation in the electromagnetic The customer or user of the UNIT should make sure that it environment specified below. is used in such an environment.
Page 53
Sirona Dental Systems GmbH 3 Electromagnetic compatibility Installation Requirements C8 Immunity interfer- IEC 60601-1-2 test level Conformance level Electromagnetic environment ence tests guidelines Portable and mobile radio equipment must not be used within the recom- mended working clearance from the...
3 Electromagnetic compatibility Sirona Dental Systems GmbH Installation Requirements C8 3.4 Working clearances Recommended working clearances between portable and mobile HF communication devices and the UNIT UNIT is intended for operation in an electromagnetic environment, where radiated HF interference is checked.