Danfoss VLT MCA 121 EtherNet/IP Manual page 52

Hide thumbs Also See for VLT MCA 121 EtherNet/IP:
Table of Contents

Advertisement

8 Appendix
Class ID 0x06 Connection Manager
Attribute Access
1
Get
2
Get
3
Get
4
Get
5
Get
6
Get
7
Get
8
Get
9
Get
Table 8.3: Instance Attributes
Class ID 0x28 Motor Data Object
Attribute
Access
1
Get
2
Get
3
Get/Set
6
Get/Set
7
Get/Set
8
8
Get/Set
9
Get/Set
12
Get/Set
15
Get/Set
Table 8.4: Instance Attributes
NB!
Class ID 0x28 is only available if ODVA profile is selected in par.8-10
Class ID 0x29 Control Supervisor Object
Attribute
Access
1
Get
2
Get
3
Get/Set
4
Get/Set
5
Get/Set
6
Get
7
Get
8
Get
9
Get
10
Get
11
Get
12
Get/Set
13
Get
15
Get
Table 8.5: Instance Attributes
52
Name
Open Requests
Open Format Rejects
Open Resource Rejects
Open Other Rejects
Close Requests
Close Format Requests
Close Other Requests
Connection Timeouts
Connection Entry List Struct of: NumCon-
nEntries
Name
Number of Attributes supported
List of attributes supported
Motor Type
Rated Current
Rated Voltage
Rated Power
Rated Frequency
Pole Count
Base Speed
Name
Number of Attributes supported
List of supported Attributes
Run 1 (forward)
Run 2 (reverse)
Network Control
State
Running 1
Running 2
Ready
Faulted
Warning
Fault reset
Fault Code
Control from net
MG.90.J2.02 - VLT
Data Type Description
UINT
Number of Forward Open requests received
UINT
Number of Forward Open requests rejected due to bad format
UINT
Number of Forward Open requests rejected due to lack of resources
UINT
Number of Forward Open requests rejected due to other reasons
UINT
Number of Forward Close requests received
UINT
Number of Forward Close requests rejected due to bad format
UINT
Number of Forward Close requests rejected due to other reasons
UINT
Number of connection timeouts
INT
Number of connection entries ConnOpenBits ARRAY of BOOL List
of connection data
Data Type
Parameter
USINT
-
Array of USINT
-
USINT
1-10
UINT
1-24
UINT
1-22
UDINT
1-20
UINT
1-23
UINT
1-39
UINT
1-25
Control Word Profile
Data Type
Description
USINT
12
Array of USINT
3,4,4,5,6,7,8,9,10,11,12,13,15
Boolean
FC CTW Bit 6 = Run1 XOR Run2
FC CTW Bit15 = 0
Boolean
FC CTW Bit 6 = Run1 XOR Run2
FC CTW Bit15 = 1
Boolean
Parameter 12-32 value written from option
USINT
The state of the CIP state-machine
Boolean
Run1 AND bit 11 in FC STW
Boolean
Run2 AND bit 11 in FC STW
Boolean
STATE_ENABLED or STATE_STOPPING or
STATE_FAULT_STOP from state-machine
Boolean
Bit 3 in FC STW
Boolean
Bit 7 in FC STW
Boolean
Bit 7 in FC CTW
UINT
Mapping of par. 16-90
fault codes
Boolean
Parameter 12-31 value written from option
®
is a registered Danfoss trademark
MCA 121 EtherNet/IP
Description
7
3,6,7,8,9,12,15
3: PM sync. motor (FC 302 only)
7: Squirrel cage induction motor
Unit: 100 mA
Unit: Volt
Unit: Watt
Unit: Hertz
Number of poles in motor
Unit: RPM
.
Alarm Word
to CIP specific