6 Parameters
12-01 IP Address
Range:
255.255.255.255]
12-02 Subnet Mask
Range:
255.255.255.255]
12-03 Default Gateway
Range:
255.255.255.255]
12-04 DHCP Server
Range:
6
255.255.255.255]
NB!
A power-cycle is necessary after setting the IP parameters manually.
12-05 Lease Expires
Range:
[dd:hh:mm:ss]
12-06 Name Servers
Option:
[0]
Primary DNS
[1]
Secondary DNS
12-07 Domain Name
Range:
Blank
[0-19 characters]
12-08 Host Name
Range:
Blank
[0-19 characters]
12-09 Physical Address
Range:
[00:1B:08:00:00:00 – 00:1B:
08:FF:FF:FF]

6.2.2 Ethernet Link Parameters

12-1* Ethernet Link Parameters
Option:
36
Function:
[000.000.000.000
-
Configure the IP address of the option. Read-only if par. 12-00 set to DHCP or BOOTP.
Function:
[000.000.000.000
-
Configure the IP subnet mask of the option. Read-only if par. 12-00 set to DHCP or BOOTP.
Function:
[000.000.000.000
Configure the IP default gateway of the option. Read-only if par. 12-00 set to DHCP or BOOTP.
Function:
[000.000.000.000
Read only. Displays the IP address of the found DHCP or BOOTP server.
Function:
Read only. Displays the lease-time left for the current DHCP-assigned IP address.
Function:
IP addresses of Domain Name Servers. Can be automatically assigned when using DHCP.
Function:
Domain name of the attached network. Can be automatically assigned when using DHCP.
Function:
Logical (given) name of option.
Function:
Read only Displays the Physical (MAC) address of the option.
Function:
Applies for whole parameter group.
MG.90.J2.02 - VLT
®
is a registered Danfoss trademark
MCA 121 EtherNet/IP

Hide quick links: