MCA 121 EtherNet/IP
8-14 Configurable Control Word CTW
Option:
[0]
None
[1] *
Profile default
[2]
CTW Valid, active low
8-50 Coasting Select
Option:
[0]
Digital input
[1]
Bus
[2]
Logic AND
[3] *
Logic OR
NB!
This parameter is active only when par.8-01
Function:
Selection of control word bit 10 if it is active low or active high
Function:
Select control of the coasting function via the terminals (digital input) and/or via the bus.
Activates Start command via the serial communication port or fieldbus option.
Activates Start command via the fieldbus/serial communication port, AND additionally via one of the
digital inputs.
Activates Start command via the fieldbus/serial communication port OR via one of the digital inputs.
Control Site
Digital and control word
is set to [0]
®
MG.90.J2.02 - VLT
is a registered Danfoss trademark
6 Parameters
.