OPERATION
MAINTENANCE
AND
INSTRUCTION MANUAL
AEU-6000-70V & AEU-6000
Implant / Endodontic Dental Systems
AEU-6000-70V System

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AEU-6000-70V and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Aseptico AEU-6000-70V

  • Page 1 OPERATION MAINTENANCE INSTRUCTION MANUAL AEU-6000-70V & AEU-6000 Implant / Endodontic Dental Systems AEU-6000-70V System...
  • Page 2: Table Of Contents

    Troubleshooting .....20 The AEU-6000-70V & AEU-6000 are drive systems for Changing the Fuse ....20 instruments and tools used in dentistry for implant/surgical Symbol Definitions .
  • Page 3: Introduction

    Your new Aseptico AEU-6000-70V & AEU-6000 Systems are two of the finest dual- function implant/endodontic motor systems available to the dental profession. The systems combine a powerful brushless 40,000 RPM motor with a wide range of handpiece ratios and precision torque controls to make the perfect dental systems for Congratulations both implant and endodontic applications.
  • Page 4: Safety Precautions

    Important additional information and hints. SAFETY PRECAUTIONS: Aseptico accepts no liability for direct or consequential injury or damage resulting from improper use, arising in particular through the non-observance of the operating instructions, or improper preparation and maintenance of this product.
  • Page 5 WARNING: Always comply with the handpiece and implant/file manufacturers’ instructions regarding maximum speeds, torques, forward and reverse directions, and use of all instrumentation, drills, burs, etc., used in endodontics, implantology, and other oral surgery applications. CAUTION: The irrigation supply system is designed for use with a saline solution or sterile water.
  • Page 6: Setting Up The Unit

    CORD IN SWITCH IN ON/OFF SWITCH Fig.3 - Setup ELECTRONIC IRRIGATION BAG CONTROL HANGER ROD CONSOLE VARIABLE-SPEED HANDPIECE FOOT CONTROL & MOTOR MOTOR CRADLE & BRACKET MOTOR RECEPTACLE DOOR RELEASE CORD CONNECTOR BUTTON IRRIGATION (AEU-6000-70V System shown) STRAIN RELIEF PUMP DOOR...
  • Page 7 b. Install Pump Tubing Assembly into pump 5. Attach the appropriate "E-Type" handpiece to door as shown in Figure 5. Install tubing the motor as shown in Figure 4. connector into the slot located on the Fig. 4 - Handpiece/Motor Connection back end of pump door.
  • Page 8: Control Panel Functions

    CONTROL PANEL FUNCTIONS: 1. Main Power Switch: with the memory card. Otherwise, the last Located on back of console (see Figure 2). settings used will initialize. Controls main power On/Off to the console. When first turned On, the System will allow the 2 Control Panel ‘Standby’...
  • Page 9: Speed Ranges

    4 Handpiece Ratio Selector: handpiece being used. Allows user to select ratio of hand- piece. Ensures accurate display of 6 Forward / Reverse (FWD/REV): speed and torque levels. Sets the rotational direction of the handpiece. a. Press the handpiece Ratio selector Up/Down buttons until a.
  • Page 10 CONTROL PANEL FUNCTIONS - Cont’d: b. Auto-Stop-Reverse Torque Mode (8:1 Note:The irrigation pump can provide handpiece ratio) - The user can specify irrigant to the handpiece at a maximum an Auto-Stop-Reverse torque mode by flow rate of 140 ml/min. depressing the (A-S/MAX) button until the (Note: Green LEDs 10 PRESETS 1 - 5: green LED illuminates, then selecting the...
  • Page 11: 11 Restoring Factory Defaults

    Wait two seconds for the Display and handpiece selected. LEDs to turn off, then turn Power Switch The System will briefly display the back 'ON' (—). As the "Aseptico" startup software version and date, then initialize marquee scrolls across the with Implant Preset-1 active. Note: When...
  • Page 12: Operation

    OPERATION: GETTING STARTED: After the unit has been version number will change with each set up and the user has become familiar with software upgrade.) Following the Start-Up the System’s control panel functions, there Screen display, the settings for Preset 1 are two different modes that can be used to will initialize and display when: the main begin operation:...
  • Page 13 When using the 8:1 (Endo) ratio, the user buttons. The handpiece will slow down can specify an Auto-Stop-Reverse torque when a load greater than the torque limit is mode by depressing the (A-S/MAX) button applied. Once the load is removed, the until the green LED illuminates, then handpiece will return to target speed.
  • Page 14 OPERATION - Cont’d: b. Insert a file, bur, or drill into the handpiece. c. Press and release the Calibration (CAL) button to activate the integrated “Free Run” Calibration program. Follow the prompts on the display: Add Handpiece To Motor Press 1> Next 3>...
  • Page 15: Operation - Presets

    OPERATION Presets new settings will overwrite the existing settings, including the factory defaults. Step 1: Adjust each of the Ratio, Speed, Torque, Flow, Rotation Direction, and Pump On/Off The five preset memory buttons are settings to the desired values via the preprogrammed at the factory with the control panel buttons (refer to Control Panel default Implant and Endodontic Presets...
  • Page 16 Chart 1 - Implant Default Presets PRESET RATIO SPEED DIRECTION TORQUE FLOW (RPM) 60,000 100% 1.67 N•cm, Torque Limit 20:1 1,200 20:1 20:1 25 N•cm, Auto Stop 20:1 32 N•cm, Auto Stop Chart 2 - Endodontic Default Presets PRESET RATIO SPEED DIRECTION TORQUE FLOW...
  • Page 17: Foot Switch Description & Operation

    The AE-70V2 Variable-Speed Foot Control Fig.9 - Variable-Speed Foot Control comes as standard equipment on the HANDLE (Removable) AEU-6000-70V System and as an option on the AEU-6000 System. The AE-70V2 can control motor speed, direction, torque, TORQUE MODE STEP-THROUGH and turn the pump On/Off. It can also MOTOR select presets.
  • Page 18 5. The Pump On/Off pad (Lower Fig.10 - Handle Installation/Removal right – Teal) turns the pump On and Off, just like the console button. Press and release the pad to turn the pump On or Off (a beep will sound). To adjust pump flow, use either the Variable-Speed Foot Control or the Up/Down Control Panel Buttons.
  • Page 19: Reprogramming The Unit

    8. When the programming is complete, the devices. These cards, available from Display will show the following message: Aseptico, enable a user to update software Programming Successful. or replace existing software that might Eject Card.
  • Page 20: Sterilization

    Sterilize NOTE: Call Aseptico Inc. at 1-800-426-5913 for any questions or clarifications on this 3) Select one of the three following sterilization procedure. sterilization methods (A. B. or C.): Wrapped Sterilization –...
  • Page 21: Maintenance & Cleaning

    SPECIFICATIONS: MAINTENANCE & CLEANING: ANDPIECES - Thorough cleaning and lubrication Console Dimensions: 8.6"W x 9.2"L x 4.8"H (22 cm x 23 cm x 12 cm) of handpieces after each use and before sterilization Console Weight: 3.9 lbs (1.8 kg) is very important to ensure proper operation and service life of the handpiece.
  • Page 22: Troubleshooting

    Then, grasp the connector body near the red dot and pull the connector straight out of the motor receptacle. CHANGING THE FUSE: W RNING NOTE: The AEU-6000-70V & AEU-6000 fea- ture auto-sensing, global voltage compatibility. The fuse indicated is correct for 100V-240V Turn the power off and unplug the unit 50/60 Hz line voltage.
  • Page 23: Symbol Definitions

    SYMBOL DEFINITIONS: Authorized European Representative Standby Switch Dangerous Voltage Alternating current Protection Against Dripping Water Protective Earth (Ground) Preset Step Through Motor Direction Torque Step Through Pump On/Off Temperature Limitation Atmospheric Pressure Limitation Part Number Humidity Limitation Serial Number Sterilize At 132°C (270°F)