PROGRAMMING

MODE SETTING

Press the Mode button to cycle through the controller's available programming modes and settings:
ON Mode, OFF Mode, TIMER Mode, AUTO Mode (4 triggers), ALARM Settings (4 settings).
ON MODE
In this mode, the fans will run continuously re-
gardless of temperature or humidity. The speed
set in this mode will be the max speed the fans
can reach in AUTO Mode.
OFF MODE
In this mode, the fans will not run regardless
of temperature or humidity. While in this mode,
pressing the up or down button will change the
display's brightness. Holding up or down button
will change the display's units F or C.
TIMER MODE
In this mode, press the up or down button to set
a time for the timer. The fans will run at the speed
set in ON Mode until the timer's clock runs out,
in which the fans will stop running. The clock will
begin counting down if no buttons are pressed
for 3 seconds. Leaving the timer mode while the
countdown is running will pause the clock until you
return to this mode.