General; Installation Guidance (Disclaimer) - GARDASOFT PP600 User Manual

Led lighting controllers
Table of Contents

Advertisement

60335-1, IEC 61010-1, IEC61558-1,-2,-16. The PSU may also be
approved to equivalent or superior safety standards.
Any energised conductors derived from mains electricity must also have
Safety Extra Low Voltage (SELV) output. Refer to
information
At maximum ratings the temperature of the enclosure can exceed 75°C.
Therefore, either all cabling must be rated to at least 100°C, or all cabling
must be additionally insulated by an appropriately rated heat resistant
sleeve or prevented from touching the metal enclosure of the controller, or
its heatsink where fitted.
Power supply cabling to the controller must be rated to at least 4A.
The cabling from the channel output to the load must be rated higher than
the maximum channel output current.
If the controller is setup incorrectly, or in the event of failure, the energy
provided by the power supply to the controller may become directly con-
nected to any or all output channels. You must consider this during install-
ation, and if necessary, provide adequate protection.
The DC power supply to controller must be externally fused to 4A using a
slow blow fuse (T4AH, 50V).
The installer must provide a clearly marked, nearby and easily accessible
switch as part of the installation to allow the controller to be disconnected
from its energy source on both power conductors.
Transients caused by inductive loads must be suppressed externally to
the PP600.
Warning:
radio interference, and such use should be avoided unless special
measures are taken by the user to restrict emissions to a level that allows
the reception of broadcast transmissions.
2.3

General

The PP600 must not be used in an application where its failure could
cause a danger to personal health or damage to other equipment.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.
2.4

Installation guidance (disclaimer)

This information is for guidance only. Installers must perform their own risk
assessment specific to each installation. While Gardasoft Vision Ltd has
taken every care in the preparation of this advice, Gardasoft Vision Ltd
accepts no liability for damages of any kind except those required by law.
Deliberate acts of endangerment and vandalism are not covered by this
document and must be considered by the installer.
for allowable voltage limits.
This is a Class A product. Its use in residential areas may cause
7
PP600/602 LED lighting controllers - User Manual
Section 10, Reference

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pp602

Table of Contents