Operating Instructions Dräger FG4200
The following can be stored: customer number, name, system type,
system place, site number, street, post code, city, customer name, cus-
tomer street, customer post code, customer city, customer phone num-
ber, boiler manufacturer, boiler type and year of manufacture, boiler
output, burner manufacturer, burner type and year of manufacture,
burner design and fuel.
The acquired customer number applies to all subsequent measure-
ments until it is switched off or another number is selected.

6. Flue gas measurement

To perform a complete flue gas measurement, we recommend a measurement time of at
least 2 minutes.
The gas outlet at the side of the device must be free and must not closed or clogged!

6.1 Connecting the flue gas probe

Turn the FG4200 on and press Next.
After the system check, the FG4200 is ready for use. Select Flue gas
measurement in the main menu.
Connect the flue gas probe to the device (see connection diagram).
Plug the jack plug of the flue gas probe in the temperature input T and
the quick-release coupling of the flue gas probe hose into the gas input
G of the measuring device. Then press Next.

6.2 Selecting fuels

Select the desired fuel and accept.
If the pump was shut off before selection of flue gas measurement func-
tion, a short stabilization phase will be performed.