Dräger Pac 7000 Instructions For Use Manual

Dräger Pac 7000 Instructions For Use Manual

Gas detector

Advertisement

Dräger Pac
Instructions for Use
en
2 - 6
Gebrauchsanweisung
de
7 - 11
Notice d'utilisation
fr
12 - 16
Instrucciones de uso
es
17 - 21
Instruções de utilização
pt
22 - 26
Istruzioni per l'uso
it
27 - 32
Gebruiksaanwijzing
nl
33 - 37
Brugsanvisning
da
38 - 42
Käyttöohjeet
fi
43 - 47
Bruksanvisning
no
48 - 52
®
7000
Bruksanvisning
sv
53 - 57
Kasutamisjuhised
et
58 - 62
Lietošanas instrukcija
lv
63 - 68
Naudojimo vadovas
lt
69 - 73
Instrukcja obsługi
pl
74 - 79
Руководство по зксплуатации
ru
80 - 85
Upute za uporabu
hr
86 - 91
Navodilo za uporabo
sl
92 - 97
Návod na použitie
sk
98 - 103
Návod na použití
cs
104 - 108
D
Ръководство за работа
bg
109 - 114
Instruc iuni de utilizare
ro
115 - 120
Használati útmutató
hu
121 - 126
Οδηγίες Χρήσης
el
127 - 132
Kullanma talimat
tr
133 - 137
ar
138 - 142
zh
143 - 147
ja
148 - 153
ko
154 - 158

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pac 7000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dräger Pac 7000

  • Page 1 ® Dräger Pac 7000 Instructions for Use Bruksanvisning Ръководство за работа 2 - 6 53 - 57 109 - 114 Gebrauchsanweisung Kasutamisjuhised Instruc iuni de utilizare 7 - 11 58 - 62 115 - 120 Notice d’utilisation Lietošanas instrukcija Használati útmutató 12 - 16 63 - 68 121 - 126...
  • Page 2: Product Overview

    – Connect Dräger Pac 7000 and the test gas cylinder to the Turning the instrument off calibration adapter or connect Dräger Pac 7000 to the Dräger Bump Test Station.
  • Page 3: Calibration

    – To enter the calibration menu press the [+] 3 times within – To change the adjusted calibration concentration press [+]. – To adjust the operation timer connect Dräger Pac 7000 to a 3 seconds. The instrument beeps twice, quickly. The notice The first digit flashes.
  • Page 4: Instrument Alarm

    Alarms – Open the front case and remove the depleted battery. 10.1 Trouble shooting errors – Press and hold [OK] for approx. 3 seconds while battery is Code Cause Remedies Concentration Pre/Main Alarms not installed. Flash / EEprom write Contact Service –...
  • Page 5: Sensor Specifications

    11.3 Sensor Specifications and Instrument Configuration Principle of measurement is an electrochemical 3-electrode sensor. Oxygen (O ) cannot be measured in the presence of Helium (He)! The Type-Examination-Certificate covers the measuring function for Oxygen enrichtment and defficiency. Cross sensitivity factors ≤...
  • Page 6 Dräger Bump Test Station “Printer” complete with test gas cylinder 58 L, including Auto Detect Function for 83 21 008 Pac 7000 (gas type by customer request) 1) Please be aware of limited lifetime of sensors. Excessive storage reduces operating time of sensors. Temperature range of storage is 0 to 35 C (32 to 95 2) Please be aware of special settings by customer requirements.

Table of Contents