Wacker Neuson AR 75/3/200/400 Operator's Manual page 10

External
Table of Contents

Advertisement

Electric power supply with residual current protective device (42 V AC)
Power supply with residual current protective device (> 50 V AC)
Extension cable
SV00079GB.fm
Note:
The rated voltage is indicated on the nameplate of your machine.
The machine may only be connected to an electric power supply with all machine
parts in proper working condition:
Mains plug.
Power cable over the entire length.
There must be at least one of the following safety devices if connected to a
stationary or mobile generator:
Transformer with safe separation in accordance with EN 60742.
Motor generator with equally separated windings.
Note:
Observe the respective national safety regulations!
Note:
The rated voltage is indicated on the nameplate of your machine.
The machine can be connected to a 15 A/16 A shock-proof plug receptacle
(continental type) with a corresponding overload protection.
One of the following fault current protective switches is required:
Standard fault current protective switch (AC sensitive, type A).
AC/DC sensitive fault current protective switch (type B).
The machine may only be connected to an electric power supply with all machine
parts in proper working condition:
Mains plug.
Power cable over the entire length.
The machine may only be connected to an electric power supply with the
protective earth (PE) connector intact.
There must be at least one of the following safety devices if connected to a
stationary or mobile generator:
Fault current protective switch
Isolation (earth leakage) monitor
IT-net
Note:
Observe the respective national safety regulations!
The machine may only be operated with undamaged extension cables!
Only use extension cables with grounded conductor and correct connection of
the grounded conductor to the plug and coupling (not for 42 V machines).
Only use extension cables which are suitable for use at construction sites:
Average rubber hose line H05RR-F or better – WACKER recommends
H07RN-F.
Immediately replace damaged extension cables (e.g. tears in the sheathing) or
loose plugs and couplings.