4.2
Automatic switch
function for
AES/compressor
refrigerator
Mains charging
starter battery
Overvoltage protection
for the EBL 30 with OVP
5.1
Dimensions
Weight
Casing
Front
5.2
Mains connection
Current consumption
Suitable batteries
Standby current from
leisure battery
D+ loading
Current-carrying
capacity
8110305 BA / EN
Instruction Manual for Electroblock EBL 30 / EBL 30 with OVP

Additional functions

This relay supplies the AES/compressor refrigerator with power from the
starter battery when the vehicle engine is running and the D+ connection is
live. An AES refrigerator is powered by the living area battery when the vehi-
cle engine is not running.
This feature provides an automatic max. 6 A float charge for the starter bat-
tery when the 230V mains is connected to the electroblock.
The electroblock is isolated from the mains within 10ms in the event of a
voltage greater than 265 V
again by itself after the mains voltage has attained the normal value.
5

Technical details

Mechanical details

130 x 275 x 170 (H x W x D in mm), including attachment feet
2.0 kg
PA (polyamide), gentian blue (RAL 5010)
Aluminium, powder coated, light grey (RAL 7035)

Electrical details

230V AC 10%, 47 -- 63 Hz sinusoidal, protection class I
1.9 A
6-cell lead-gel or AGM batteries, 55 Ah and above
Dependent on the control panel: approx. 5 -- 20 mA, plus consumption of
controller electronics of refrigerator
Conditions for the measurement:
approx. 10 minutes after disconnection from the mains
F
12.6 V battery voltage
F
Battery alarm OFF
F
Battery cut-off switch ON
F
Lighting for operator and control panel OFF
F
All consumers switched off
F
12V main switch off
F
Loading of D+ output of the alternator by the electroblock approx. 0.5 mA
without current consumption on D+ point
12V outputs
Frost protection valve output
D+ point
Date: 15.10.2018
eff. The electroblock switches itself back on
A maximum of 90% of the nominal
current of the relevant fuse may be
drawn.
max. 0.1 A
1 A for fusing D+ input with 2 A
9