Operating Faults - Schaudt Electroblock EBL 30 Instruction Manual

Hide thumbs

Advertisement

3.3
Flat vehicle fuses
Discharged battery - -
start motor
8110305 BA / EN
Instruction Manual for Electroblock EBL 30 / EBL 30 with OVP
Faults
A flat battery or defective fuse is the cause of most faults in the power sup-
ply system.
If the battery is discharged, consumers can always be powered by starting
the engine of the base vehicle.
Please contact our customer service address if you cannot rectify the fault
using the following table.
If this is not possible, e.g. if you are abroad, you can have the electroblock
repaired at a specialist workshop. In this case, you must ensure that the
warranty is not invalidated by incorrect repairs being carried out. Schaudt
GmbH will not accept any liability for damage resulting from such repairs.
Fault
Leisure area battery is not
y
charged during 230V ope-
h
d d i
230V
ration (battery voltage
ration (battery voltage
constantly below 13.3 V)
y
Living area battery is over-
charged during 230V ope-
ration (battery voltage
constantly above 14.5 V)
Starter battery is not char-
y
ged during 230V opera-
d d i
230V
tion (battery voltage con-
tion (battery voltage con-
stantly below 13.0 V)
y
Leisure battery is not
charged during mobile
g
g
operation (battery voltage
ti
(b tt
below 13.0 V)
The leisure battery is
overcharged during mo-
bile operation (battery vol-
tage permanently above
14.3 V)
The refrigerator does not
work during mobile opera-
tion
Solar charging does not
Solar charging does not
work
Date: 15.10.2018
Possible cause
No mains voltage
g
)
Too many consumers are
switched on
Defective electroblock
Defective electroblock
No mains voltage
g
)
Too many consumers are
switched on
Defective electroblock
Defective alternator
lt
No voltage on D+ input
Defective electroblock
Defective alternator
No power supply to the re-
frigerator
Defective electroblock
Defective refrigerator
Solar charge regulator not
Solar charge regulator not
plugged in
Defective fuse or cabling
Solar charge regulator de-
fective
Remedy
Switch on the automatic
circuit breaker in the vehi-
i
i b
k
i
h
hi
cle; check the mains vol-
cle; check the mains vol-
tage
Switch off any consumers
not required
Contact customer service
Contact customer service
Switch on the automatic
circuit breaker in the vehi-
i
i b
k
i
h
hi
cle; check the mains vol-
cle; check the mains vol-
tage
Switch off any consumers
not required
Contact customer service
Have the alternator chek-
ked
Have the fuse and cabling
checked
Contact customer service
Have the alternator chek-
ked
Have the fuse (20A of sup-
ply; possibly 2A of the D+
signal) and wiring checked
Contact customer service
Havetherefrigeratorchek-
ked
Plug in solar charge regu-
Plug in solar charge regu
lator
Have the fuse and cabling
checked
Have solar charge regula-
tor checked