Closing Down The System - Schaudt Electroblock EBL 30 Instruction Manual

Hide thumbs

Advertisement

Instruction Manual for Electroblock EBL 30 / EBL 30 with OVP
Closing down
6
Fault
12V supply does not work
in the leisure area
in the leisure area
The charging current is reduced automatically if the device becomes too
Y
hot due to excessive ambient temperature or lack of ventilation. Always
prevent the device from overheating nevertheless.
If the automatic shutdown mechanism of the battery monitor is triggered,
Y
fully charge the living area battery.
3.4

Closing down the system

The battery is isolated by switching off the battery cut-off switch.
ATTENTION!
Y
Total discharge.
Damage to the leisure area battery:
Fully charge the living area battery before and after closing down the
F
system. (Connect vehicle to the mains with an 80Ah battery at least
12 hours and with a 160Ah battery at least 24 hours).
Disconnect the living area battery from the 12V power supply if the motor-
home is not used for a longer period (during the winter for example).
Fully charge the living area battery before closing down the system.
"
Switch off the main switch on the IT ... / LT ... control and display panel.
"
Move the battery cut-off switch (see Fig. 4, Pos. 12) to the "Battery OFF"
"
position. The following connections are isolated from the living area bat-
tery:
All 12V consumers
F
Frost protection valve
F
Operator and control panel
F
The living area battery is then protected against total discharge. This only
applies if the battery is intact. Follow the battery manufacturer's instructions.
If the living area battery is isolated from the electroblock with the battery
Y
cut-off, the frost protection valve of the combination heater opens. A loss
of water is possible (see the operating instructions for the combination
heater).
Possible cause
12V main switch for the li-
ving area battery is swit-
ving area battery is swit
ched off
Not all plugs/fuses are
plugged into the electro-
plugged into the electro
block
Defective fuse or cabling
Defective fuse or cabling
Defective electroblock
Date: 15.10.2018
Remedy
12V main switch for the li-
ving area battery must be
ving area battery must be
switched on
Pug all plugs and fuses
(correct ratings) into the
(correct ratings) into the
electroblock
Have the fuse and cabling
Have the fuse and cabling
checked
Contact customer service
8110305 BA / EN