MACHINE_ERR_06

Error
Code
06
Timeout error on the node authentication

MACHINE_ERR_07

Error
Code
Multiple destinations are set in the Client-side
07
Machine.

MACHINE_ERR_08

Error
Code
• A Client-side Machine connects to other
08(1)
• The Client-side Machine not registered in
• A Remote Machine connects to other
08(2)
• Wrong Remote Machine registered in
72
Suggested Cause
Suggested Cause
Suggested Cause
Client-side Machine.
the Remote Machine as destinations.
Remote Machine.
the Client-side Machine.
Action
Adjust the value of SP5-741-001 to
prolong the timeout for node
authentication.
Action
In the Client-side Machine, execute
SP5-801-021 to clear AICS memory
Action
• Connect to the Remote Machine.
• Register the Client-side Machine to
the Remote Machine as a
destination.
• Connect to the Client-side
Machine.
• Check what Remote Machine
registered in the Client-side
Machine.