Revision Lists Version Section Details Initial release of this document. 1.00 Created this manual for D176/D177 series. Revised all sections according to the 1.10 release of D197 series Modified some parts name. Read This First > Safety and Symbols Added this section. Installation >...
Page 4
Version Section Details Mechanism > Power Supply Control > Added this procedure. Special Shutdown System Maintenance > Version Update > Preparing Version Update Added this item. SD card Modified the description. System Maintenance > Version Update > Version Update Procedure Modified some keys name.
Safety and Symbols This manual uses several symbols and abbreviations. The meaning of those symbols and abbreviations are as follows: Clip ring Screw Connector Clamp Short Edge Feed Long Edge Feed [A] Short Edge Feed (SEF) [B] Long Edge Feed (LEF) Trademarks ®...
TABLE OF CONTENTS Revision Lists................................1 Safety and Symbols............................3 Trademarks..............................3 1. Replacement and Adjustment Operation Panel Unit............................7 Operation Panel.............................7 Microcomputer Board............................8 CPU Board..............................11 I/O Board..............................12 Speaker................................13 LCD................................13 Microphone..............................15 2. Mechanism Overview................................17 System Components............................17 Specification............................18 Available languages...........................19 Appearance/Screen Layout........................19 1. Key specification..........................19 2.
Page 7
Reset Procedure If the Android Screen Freezes................27 Maintenance Modes...........................27 Version Update............................28 Preparing Version Update SD card....................28 Version Update Procedure.........................28 Application Installation/Version Update....................31 Version update via SD card.......................31 Self-Diagnosis..............................31 SP Mode List..............................36 Settings Menu List............................36 Recovery Menu..............................39...
Page 11
Operation Panel Unit Remove four screw covers. Operation panel rear cover [A] ( ×4, hook×4) • There are 4 hooks inside the operation panel. Before removing the operation panel rear cover, see the photos below.
Page 12
1. Replacement and Adjustment Operation panel arm bracket [A] ( ×7, ×3, ×1) Bracket [A] ( ×6)
Page 16
1. Replacement and Adjustment I/O Board (page Speaker (page Remove the LCD with the bracket [A] ( ×2). Remove the bracket [A] from the LCD ( ×4).
2. Mechanism Overview System Components The Android control unit is a control unit in which the Android OS connected with the MFP by USB, is installed. [A]: Android screen [B]: Android firmware (update from recovery mode) [C]: Android application (perform installation version update from screen SP mode)
Overview Available languages Japanese, American English, German, French, Italian, Spanish, Dutch, Russian, Chinese (simplified Chinese characters) and Chinese (traditional Chinese characters) Appearance/Screen Layout The Android control unit is a control unit in which the Android OS connected with the MFP by USB, is installed.
2. Mechanism Description Status check Change to status display screen. Stop Change to stop screen. Return to previous screen. (The return destination may be the Back home screen). Change to the menu screen of a displayed application. In case of Menu an application without a menu screen, it does not operate.
Overview 3. External I/F specification External I/F Description Available from both GW application/Android application. SD card slot (to use, change over). USB slot Available only from GW application mini USB slot Not available 4. Screen layout Part name Description Application screen area This is the application display area.
2. Mechanism Electrical Components Item Description Board with microcomputer which performs (energy- Microcomputer board save) power supply control of the control unit Speaker Board with external IF connector (also, a WLAN I/O board module) CPU board Main board with main control CPU LCD (liquid crystal) I/F cable Small gauge coaxial...
Power Supply Control Power Supply Control Energy-Save Recovery Operation An Android screen is different from a conventional screen (standard screen) in the method of recovery from energy-saving mode. Android control unit Standard control unit Perform energy-save recovery, and display home screen. HOME Does not recover.
2. Mechanism Android control unit Standard control unit Login/logout No key Does not recover. Screen Startup Mode As control unit start-up modes, a Normal Startup Mode (power-saving mode) and Quick Startup Mode are provided. Each mode can be changed over from Screen Features Screen Device Settings Screen Startup Mode.
Power Supply Control 3. The power LED blinks. 4. The power LED turns off. Special Shutdown To facilitate maintenance, the following two shutdown procedures are provided: 1. Maintenance shutdown (shortens shutdown time) When the Quick Startup Mode is set, preparations for the next start-up are performed during shutdown, so shutdown takes more time than in normal start-up mode.
3. System Maintenance System Maintenance Basic Operation Switching the Power OFF before Performing Maintenance (before Disconnecting the Power Supply Plug) Press the power switch while pressing the [STOP] key. Continue pressing the [STOP] key until "Shutting Down" is displayed. • Shutdown can be performed in a short time even when the Quick Startup Mode is set. Switching the Power OFF before Upgrading the MFP (Controller/Engine) Version Press the power switch while pressing the [STOP] key.
3. System Maintenance Mode Application Remarks Since a 10-keypad is used for MFP (engine) mode shift, mode shift must be MFP SP mode performed from a GW • Conventional SP mode application. Android-specific screen service mode • Android application installation and Screen service mode Idem version update...
Page 31
System Maintenance • If firmware update is required with the above settings, ask customer (machine administrator) to request a change of the setting. Turn off the main power. Insert the SD card in the control unit SD slot, and start the recovery mode. Select "apply update from sdcard.", and press [Home] key.
Page 32
3. System Maintenance The installation screen is displayed. The current version of the firmware, and the update version of the firmware in the SD card are displayed. Check that the version is correct. When "Continue Update?" is displayed, press OK ([HOME] key). Version Update is started.
System Maintenance Application Installation/Version Update Version update via SD card Preparing the version update SD card Download the update file. (.zip) Create the folder “app” on root directly. Move the downloaded file to the app folder. • Do not unzip the downloaded file. Version Update Procedure Shift to screen service mode.
Page 34
3. System Maintenance • Data in • USB access • HOME • Status check (When lit, R->G->B->R->G->B is repeated at 500 ms intervals) • BACK/MENU • FAX • SD access 2. Key check Check pressing hard keys other than the [HOME] key on the control unit. When a key is depressed, the corresponding key displayed on the control unit is shown highlighted.
Page 35
System Maintenance 4. Speaker check The following standard sounds are generated according to the button instructions on the screen. • Frequency: 220 Hz, 440 Hz, 880 Hz, 1760 Hz, 2000 Hz • Sound volume: 16 levels from minimum to maximum •...
Page 36
3. System Maintenance 6. Touch panel check Displays the difference of a detection coordinate value from the nearest reference point relative to a standard 9 points on the screen. 7. Touch panel calibration Perform a touch-panel calibration, and set a value. One + mark after another is displayed at locations (5 points) required for calibration.
Page 37
System Maintenance When it is desired to set the current value, the operation is completed by pressing the "Menu" key, and the display returns to the self-diagnosis screen. To repeat the setting, or to stop touch panel calibration, press the Back key. When the Return key is pressed, a + mark is displayed in the first position for performing calibration.
3. System Maintenance SP Mode List Settings Menu List Menu level Description Level 1 Level 2 Level 3 Application Install from SD card Update by installing application (installation of from SD card. application). Installation / update / Activation can be performed activation using a SD card.
Page 39
SP Mode List Menu level Description Level 1 Level 2 Level 3 Voice input/ Setting of text read- Play back a short sample of Play back a output aloud speech synthesis with the present sample setting. When not using the speech Always use your synthesis setting of each own settings...
Page 40
3. System Maintenance Menu level Description Level 1 Level 2 Level 3 Device setting Port number Server setting (input: 1-65535) Control unit self- Perform self-diagnosis of control diagnosis unit.
Recovery Menu Recovery Menu Menu Description System reboot Reboot system now (used to come out of recovery mode) apply update from sdcard Android firmware (OS) version update wipe data/factory reset Full format wipe cache partition wipe free area partition...