Osburn Beyond Fire 1700 Installation And Operation Manual page 33

Table of Contents

Advertisement

8.1.2
With Lowered Ceiling
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
Canada
A
14 ½" (368 mm)
B
12" (305 mm)
C
13" (330 mm)
L
78" (1981 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
2
WITH SINGLE WALL PIPE CONNECTOR
Canada
D
18" (457 mm)
E
21" (533 mm)
F
21 ¾" (552 mm)
8.1.3
With Heat Shield AC02710 and Lowered Ceiling
To reduce the clearances of an appliance using a single wall pipe connector, the use of a heat
shield certified with the single wall pipe connector to be used as close as 6" from combustible
materials must be used. Only in this case, the same clearances as a certified double wall pipe
connector can be used.
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
2 ½" (64 mm)
B
2 ½" (64 mm)
C
2 ½" (64 mm)
78" (1981 mm)
L
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above
2
mentioned.
Installation and Operation Manual - 1700
USA
14 ½" (368 mm)
12" (305 mm)
13" (330 mm)
78" (1981 mm)
FROM PIPE CONNECTOR
USA
18" (457 mm)
21" (533 mm)
21 ¾" (552 mm)
USA
2 ½" (64 mm)
2 ½" (64 mm)
2 ½" (64 mm)
78" (1981 mm)
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
9 ½" (241 mm)
B
12" (305 mm)
C
13" (330 mm)
L
78" (1981 mm)
DISTANCES
FROM PIPE CONNECTOR
2
WITH DOUBLE WALL PIPE CONNECTOR
Canada
13" (330 mm)
D
E
21" (533 mm)
F
21 ¾" (552 mm)
DISTANCES
FROM PIPE CONNECTOR
2
WITH DOUBLE WALL PIPE CONNECTOR
Canada
D
6" (152 mm)
E
11 ½" (292 mm)
F
11 ¼" (286 mm)
USA
9 ½" (241 mm)
12" (305 mm)
13" (330 mm)
78" (1981 mm)
USA
13" (330 mm)
21" (533 mm)
21 ¾" (552 mm)
USA
6" (152 mm)
11 ½" (292 mm)
11 ¼" (286 mm)