Curve 4
Curve 4 is a custom curve based on the target setpoint temperature of the boiler the customer
selects. The maximum temperature is the target temperature. The minimum temperature is 36°F
lower than the target temperature with a minimum of 104°F. See example curves below.
190°F
(88°C)
180°F
(82°C)
170°F
(77°C)
170°F
(77°C)
160°F
(71°C)
150°F
(66°C)
150°F
(66°C)
140°F
(60°C)
130°F
(54°C)
130°F
(54°C)
120°F
(49°C)
104°F Minimum
110°F
Temperature
(43°C)
100°F
(38°C) -20°F
-10°F
(-29°C)
(-23°F)

Select Reset Curve

To select the desired reset curve, access the parameters (as shown in section "12.4 Parameter
Settings") and select parameter
Parameter
Number
01
92
14°F
(-10°C)
0°F
10°F
20°F
(-18°C)
(-12°C)
(-7°C)
01
. Then, select the desired curve.
Setting Description
Outdoor reset curve
30°F
40°F
50°F
(-1°C)
(4°C)
(10°C)
Selection
A
1
2
Rinnai I-Series Condensing Boiler Combi Manual
68°F
(20°C)
134°F
(57°C)
114°F
(46°C)
104°F
(40°C)
60°F
70°F
(16°C)
(21°C)
C
3
4