Performance Data Table - Rinnai I Series Installation And Operation Manual

Wall-mounted, gas-fired combi boiler, central heating and domestic hot water
Hide thumbs Also See for I Series:
Table of Contents

Advertisement

IMPORTANT
Unit of measurement (°F/°C, PSI/bar, and GPM/LPM) will vary depending on unit of
measure selection.
#
DATA
0 1
Water Pressure
02
Water Flow Rate
03
Supply Temperature
04
Return Temperature
05
Freeze Protection Temperature
06
Exhaust Temperature
07
Outgoing Temperature
08
Inlet Temperature
1 0
Heat Exchanger Outlet Temperature
1 1
Fan Frequency
1 3
Water Flow Control Position
14
Bypass Flow Control Position
15
3-Way Valve Control Position
16
3-Way Valve Control Cycles
17
Venturi Position
18
Venturi Cycles
20
Pump Cycles
21
Pump Hours
22
Pump for Boiler
2 3
Pump for System (Pump 1)
2 4
Pump for System (Pump 2)
31
Outdoor Temperature
32
Additional Controllers Connected
40
Energization Hours
41
Combustion Hours
42
Combustion Cycles
43
Combustion Hours (DHW)
44
Combustion Cycles (DHW)
4 5
Commissioning Cycles
* Refer to the Technical Data Sheet located on the inside front cover of the boiler for additional
information.
Rinnai I-Series Condensing Boiler Combi Manual
UNIT
PSI/bar
x0.1 GPM/LPM
°F/°C
°F/°C
°F/°C
°F/°C
°F/°C
°F/°C
°F/°C
Hz
0=Mid, 1=Open, 2=Closed
Degrees of Opening
0=Mid, 1=DHW, 2=CH
x100
0=Closed, 1=Open
x100
x100
x10 Hours
0=OFF, 1=ON
0=OFF, 1=ON
0=OFF, 1=ON
°F/°C
*
x100 Hours
x10 Hours
x100
x10 Hours
x100
x1
79