Dip Switch Settings - Rinnai I Series Installation And Operation Manual

Wall-mounted, gas-fired combi boiler, central heating and domestic hot water
Hide thumbs Also See for I Series:
Table of Contents

Advertisement

DIP
Function
Switch #
1
Outdoor
Temperature Sensor
2
Thermostat Usage
3
DHW Recirculation
4
Simultaneous Central
Heating and
Domestic Hot Water
5
Gas Valve Solenoid
6
Altitude Setting
7
Altitude Setting
8
Vent Type Selection
Rinnai I-Series Condensing Boiler Combi Manual
Description
Enables or Disables the
Outdoor Temperature
Sensor
Changes the mode
between Thermostat
Usage and Central
Heating Button
Enables the DHW
Recirculation function for
Pump 2 connection
Enables simultaneous
operation between
Central Heating and
Domestic Hot Water
Shuts down the
integrated solenoid gas
valve manually
Sets the appropriate
elevation of the boiler
installation
Selects the venting
material used. The boiler
is set from the factory to
be installed in a PVC
venting system. If CPVC,
PP, or other approved
venting is used, this
setting may be adjusted.
See section "5.4 PVC
Venting Safety Switch" for
more information.
OFF (Default)
Outdoor
Temperature
Temperature
Sensor in Use
Sensor Not in
Thermostat Used
Central Heating
ON button used.
Boiler fires based
on return water
temperature
DHW Recirculation
OFF (Pump 2
recirculation ON
connection for
Zone Pump 2)
connection for
DHW Pump)
Domestic Hot
Simultaneous
Water Priority
Central Heating
Domestic Hot
Water Permitted
Normal Operation
Fixed Closed
Depends on Altitude
PVC
ON
Outdoor
Use
DHW
(Pump 2
and
Other
81