Rinnai I Series Installation And Operation Manual page 101

Wall-mounted, gas-fired combi boiler, central heating and domestic hot water
Hide thumbs Also See for I Series:
Table of Contents

Advertisement

140
Heat Exchanger Overheat
Overheat switch is tripped.
Measure the resistance of the Overheat
Switch.*
Check the heat exchanger surface for hot
spots which may indicate blockage due
to scale buildup.
Ensure the boiler pump is not locked up.
Ensure that all of the valves in the CH
circuit are open.
Ensure the boiler and CH circuit does not
have a freezing condition.
The surface of the heat exchanger may
turn to a black color as stainless steel is
tempered even in normal conditions.
This does not indicate an abnormal
condition.
Check for damage on the exhaust, seal,
and venting.
150
Venturi Control
Venturi operation error.
Ensure the venturi motor is operating
correctly.*
Replace the gas valve assembly.
High Outgoing Temperature
161
Safety shutdown because DHW outgoing
temperature is too hot.
Check sensor wiring for damage of
outgoing thermistor.
Measure resistance of outgoing
thermistor.*
Ensure the gas valve has no damage and
the orifice is installed correctly.
Replace the gas valve assembly.
Venturi Blockage
170
Check the venturi and silencer for
blockage.
Before resetting this error, check if the
condensate drain is block and if the
venting is connected properly.
Electrical Grounding
190
Secondary circuit ground fault.
Check all electrical components for
electrical short.
Condensate Pump (Accessory)
250
Boiler will operate for 60 seconds.
Confirm wire connections and
harnesses are good.
Ensure the condensate reservoir is
empty and condensate pump is
operational.
* See "Electrical Diagnostics" on Technical Data Sheet located on inside front cover of boiler.
Rinnai I-Series Condensing Boiler Combi Manual
341
Inlet Thermistor
Check sensor wiring for damage.
Measure the resistance of the sensor.
Replace if necessary.
353
Supply Thermistor
Check sensor wiring for damage.
Clean the surface of the sensor.
Measure the resistance of the sensor.
Check the return thermistor.
Replace if necessary.
321
Outgoing Thermistor
Check sensor wiring for damage.
Clean sensor of any scale buildup
present.
Measure the resistance of the sensor.
Replace if necessary.
331
Heat Exchanger Thermistor
Check sensor wiring for damage.
Measure the resistance of the sensor.
Replace if necessary.
310
Freeze Protection Thermistor
Check sensor wiring for damage.
Measure the resistance of the sensor.
Replace if necessary.
380
Exhaust Thermistor
Check sensor wiring for damage.
Clean the surface of the sensor.
Measure the resistance of the sensor.
Check the return thermistor.
Replace if necessary.
363
Return Thermistor
Check sensor wiring for damage.
Measure the resistance of the sensor.
Replace if necessary.
393
Outdoor Thermistor
Ensure that DIP switch 1 is set to the
appropriate position.
Check sensor wiring for damage.
Measure the resistance of the sensor.
Replace if necessary.
400
Pressure Sensor
Check sensor wiring for damage.
Measure the voltage of the sensor.
Replace if necessary.
101