Maintenance Section

Engine Oil and Filter - Change

Perkins recommends using a sampling valve in order
to obtain oil samples. The quality and the consistency
of the samples are better when a sampling valve is
used. The location of the sampling valve allows oil
that is flowing under pressure to be obtained during
normal engine operation.
Obtain the Sample and the
Analysis
Hot oil and hot components can cause personal
injury. Do not allow hot oil or hot components to
contact the skin.
In order to help obtain the most accurate analysis,
record the following information before an oil sample
is taken:
• The date of the sample
• Engine model
• Engine number
• Service hours on the engine
• The number of hours that have accumulated since
the last oil change
• The amount of oil that has been added since the
last oil change
Ensure that the container for the sample is clean and
dry. Also ensure that the container for the sample is
clearly labelled.
To ensure that the sample is representative of the oil
in the crankcase, obtain a warm, well mixed oil
sample.
To avoid contamination of the oil samples, the tools
and the supplies that are used for obtaining oil
samples must be clean.
The sample can be checked for the following: the
quality of the oil, the existence of any coolant in the
oil, the existence of any ferrous metal particles in the
oil and the existence of any nonferrous metal
particles in the oil.
Engine Oil and Filter - Change
Hot oil and hot components can cause personal
injury. Do not allow hot oil or hot components to
contact the skin.
Do not drain the oil when the engine is cold. As the oil
cools, suspended waste particles settle on the
bottom of the oil pan. The waste particles are not
removed with the draining cold oil. Drain the
crankcase with the engine stopped. Drain the
crankcase with the oil warm. This draining method
allows the waste particles that are suspended in the
oil to be drained properly.
Failure to follow this recommended procedure will
cause the waste particles to be recirculated through
the engine lubrication system with the new oil.
Drain the Engine Oil
After the engine has been run at the normal
operating temperature, stop the engine. Use one of
the following methods to drain the engine crankcase
oil:
• If the engine is equipped with a drain valve, turn
the drain valve knob counterclockwise in order to
drain the oil. After the oil has drained, turn the
drain valve knob clockwise in order to close the
drain valve.
• If the engine is not equipped with a drain valve,
remove the oil drain plug in order to allow the oil to
drain. Discard the washer. If the engine is
equipped with a shallow sump, remove the bottom
oil drain plugs from both ends of the oil pan.