SEBU8313-02
Containers of several sizes are available. Consult
your Perkins dealer or your Perkins distributor for the
part numbers.
ELC Cooling System Maintenance
Correct additions to the Extended Life
Coolant
NOTICE
Use only Perkins products for pre-mixed or concen-
trated coolants.
Mixing Extended Life Coolant with other products re-
duces the Extended Life Coolant service life. Failure
to follow the recommendations can reduce cooling
system components life unless appropriate corrective
action is performed.
In order to maintain the correct balance between the
antifreeze and the additives, you must maintain the
recommended concentration of Extended Life
Coolant (ELC). Lowering the proportion of antifreeze
lowers the proportion of additive. This will lower the
ability of the coolant to protect the system from
pitting, from cavitation, from erosion, and from
deposits.
NOTICE
Do not use a conventional coolant to top-off a cooling
system that is filled with Extended Life Coolant
(ELC).
Do not use standard supplemental coolant additive
(SCA).
When using Perkins ELC, do not use standard SCA's
or SCA filters.
ELC Cooling System Cleaning
Note: If the cooling system is already using ELC,
cleaning agents are not required to be used at the
specified coolant change interval. Cleaning agents
are only required if the system has been
contaminated by the addition of some other type of
coolant or by cooling system damage.
Clean water is the only cleaning agent that is
required when ELC is drained from the cooling
system.
After the cooling system is drained and after the
cooling system is refilled, operate the engine while
the cooling system filler cap is removed. Operate the
engine until the coolant level reaches the normal
operating temperature and until the coolant level
stabilizes. As needed, add the coolant mixture in
order to fill the system to the specified level.
Changing to Perkins ELC
To change from heavy-duty antifreeze to the Perkins
ELC, perform the following steps:
NOTICE
Care must be taken to ensure that all fluids are con-
tained during performance of inspection, mainte-
nance, testing, adjusting and the repair of the
product. Be prepared to collect the fluid with suitable
containers before opening any compartment or disas-
sembling any component containing fluids.
Dispose of all fluids according to local regulations
and mandates.
1. Drain the coolant into a suitable container.
2. Dispose of the coolant according to local
regulations.
3. Flush the system with clean water in order to
remove any debris.
4. Use Perkins cleaner to clean the system. Follow
the instruction on the label.
5. Drain the cleaner into a suitable container. Flush
the cooling system with clean water.
6. Fill the cooling system with clean water and
operate the engine until the engine is warmed to
49° to 66°C (120° to 150°F).
NOTICE
Incorrect or incomplete flushing of the cooling system
can result in damage to copper and other metal
components.
To avoid damage to the cooling system, make sure to
completely flush the cooling system with clear water.
Continue to flush the system until all the signs of the
cleaning agent are gone.
7. Drain the cooling system into a suitable container
and flush the cooling system with clean water.
Note: The cooling system cleaner must be
thoroughly flushed from the cooling system. Cooling
system cleaner that is left in the system will
contaminate the coolant. The cleaner may also
corrode the cooling system.
8. Repeat Steps 6 and 7 until the system is
completely clean.
9. Fill the cooling system with the Perkins Premixed
ELC.