Connectable components
7.2 MCP 310C PN
7.2.3.1

Description

X10 power supply pin assignment
Connector designation: X10
Connector type: Terminal block, 3-pin plug connector
Pin
1
2
3
PLC I/O Interface pin assignment
Connector designation: X20, X21
Connector type: RJ45 socket
Table 7- 16
Pin
1
2
3
4
5
6
7
8
Rotary switch: Feed override X30 / spindle override X31
Connector designation: X30/X31
Connector type: 2 x 5-pin plug connector, acc. to EN 60603-13 with coding
Table 7- 17
Pin
1
2
3
4
122
Signal name
Signal type
P24
V
M24
V
SHIELD
V
Assignment of connectors X20, X21
Signal name
Signal type
TX+
I
TX-
I
RX+
O
N.C.
-
N.C.
-
RX-
O
N.C.
-
N.C.
-
Assignment of connector X30
Signal name
Signal type
N.C.
-
N.C.
-
M
V
N.C.
-
Meaning
24 V potential
24 V ground
Shield connection
Meaning
Transmit +
Transmit -
Receive +
Not assigned
Not assigned
Receive -
Not assigned
Not assigned
Meaning
Not assigned
Not assigned
Ground
Not assigned