Connectable components
7.5 PP 72/48D PN
LED displays
For diagnostic purposes, the RJ45 sockets are each equipped with a green and a yellow
LED. This allows the following information on the respective PROFINET port to be displayed:
Table 7- 30
Name
Link
Activity
PROFINET address (S1)
The right logical address must be assigned to the I/O module for communication with PLC
I/O interface using the 10 bit DIP switch S1.
Table 7- 31
1
on
off
on
off
on
The device name consists of the PROFINET name and the device number: in the case of I/O
Note
A newly set PROFINET address will only come into effect after power OFF/ON.
The switch positions 9 and 10 guarantee the PROFINET functionality of the module and
must always be switched "on".
158
PROFINET ports LED displays
Color
Green
Yellow
Switch S1 settings
2
3
4
5
off
off
on
off
off
off
on
off
on
on
off
off
on
on
off
off
off
on
off
off
modules, the 1st module is device number 9.
Status
Meaning
Lit
100 Mbit link available
Off
Missing or faulty link
Lit
Sending or receiving
Off
No activity
6
7
8
9
10
on
on
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
Device name
Meaning
pp72x48pn9
1st PP module
pp72x48pn8
2nd PP module
pp72x48pn7
3rd PP module
pp72x48pn6
4th PP module
pp72x48pn5
5th PP module