Emergency Error Codes - Omron E3NW-CCL User Manual

Cc-link digital sensor communications unit
Table of Contents

Advertisement

7 Troubleshooting and Maintenance
7-1-4

Emergency Error Codes

The following tables gives the meanings of the emergency error codes used by the E3NW-CCL Sensor
Communications Unit.
E3NW-CCL Error Codes
Error code
0×01
Communications Error
0×02
Set Value Error
0×04
Status Error
0×08
Command Error
0×10
TRG Error
7 - 6
Error name in error
Error details
history
Checksum error, timeout
error, etc.
The command data value
is invalid. (For example, it
is out of range.)
• Tuning failed.
• Hysteresis width data
is out of range.
• Timer data is out of
range.
The Sensor Amplifier is
currently not in a state
that can accept the
command.
• Command was
received in Setting
Mode.
• A command for the
second point for
two-point tuning was
received, but not for
the first point.
• A command for the
second point for
positioning tuning was
received, but not for
the first point.
An unsupported
command was sent to the
Sensor Amplifier Unit.
• A command that could
not be executed was
sent.
• A channel that does
not exist was specified.
• Multiple Sensor Units
were specified in a
read command.
TRG was turned OFF
before processing was
finished.
E3NW-CCL CC-Link Digital Sensor Communications Unit User's Manual (E431)
Notification to CC-Link
master
The error code is stored in the
Error Information Storage
Area remote register
(RWrm+5) and the Error
Status Flag remote input relay
(RX(n+3)A in Reduced I/O
Mode and RX(n+13)A in
Monitor Mode) turns ON.
Solution
• Retry.
• Check
communications
with the Sensor
Unit.
Set the correct data.
Send the commands
at the correct time.
Set the correct
command.
Keep TRG ON until
processing is
finished.

Advertisement

Table of Contents
loading

Table of Contents