Error Codes - Omron CompoNetT E3NW-CRT User Manual

Digital sensor communications unit
Table of Contents

Advertisement

Explicit message
One-point Tuning
Performs one-point tuning.
Flashing
Flashes the light.
Clear Flashing
Stops flashing of the light.
Initialize
Resets all internal Sensor
Amplifier Unit set values to their
default settings.
Tuning without a
Performs tuning without a
Workpiece
workpiece.
*1:The valid unit number range for the instance ID is 0001 to 0020 hex.

Error Codes

Response code
Error name
0x08FF
Service
not supported
0x14FF
Invalid
Attribute value
0x16FF
Object
does not exist
0x15FF
Too much data
0x13FF
Not enough
data
0x0CFF
Object state
conflict
0x20FF
Invalid
Parameter
0x0EFF
Attribute
not settable
OK: Supported, NA: Not supported, ---: To communication unit
Function
An error was detected in the service code.
The specified attribute value is not supported.
The written data is out of range.
• The number of connected Sensors is not within between 1 and 16.
• The number of Units specified for detection level monitoring is not
between 1 and 16.
The specified instance ID is not supported.
• The unit number specified in the instance ID exceeds the number of
connected Sensors.
The data is longer than the specified size.
The data is shorter than the specified size.
The specified command cannot be executed.
• An error occurred in communications with the Sensor Amplifier Unit.
• The Sensor Amplifier Unit is not in Detection Mode.
• A command was sent to perform second-point tuning for two-point
tuning or positioning tuning without performing tuning for the first point.
• An unsupported command was sent. (For example, a command to read
digital values was sent to a Terminal Block Unit.)
The specified operation execution data is not supported.
A write service code was sent with a read-only attribute ID.
Explicit Message Communications
Command
Class
Instance
Attribute
ID
ID
ID
0x9E
Unit No./
0xDE
Output
0x9E
Unit No.
0xDF
0x9E
Unit No.
0xE0
0x9E
Unit No.
0x45
0x9E
Unit No./
0xE2
Output
Cause
Section 3
Applicable Sensor
Amplifier Units
FA0
LA0
SA0
NA
NA
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
NA
NA
OK
E3NW-CRT
59
User's Manual

Advertisement

Table of Contents
loading