Detailed description
2.4 Actions in synchronized actions
Delete wait marker
The command CLEARM (marker number) can be programmed in the part program and the
action section of a synchronized action. It deletes the marker (marker number) for the
channel in which the command is applied (own channel).
2.4.22
Set alarm/error reactions
Fault situations
Setting an alarm is one way of reacting to error states.
Application:
The SETAL command can be programmed to set cycle alarms from synchronized actions.
The following reactions can also be programmed as a response to errors:
• For stopping the axis, refer to Subsection 2.4.12 "Disabling a Programmed Axis
• For setting the output, refer to Subsection 2.4.2 "Setting (Writing) and Reading of real-
• Other actions listed in Section 2.4 "Actions in Synchronized Actions"
Example set alarm
D=67 WHENEVER $AA_IM[X1] - $AA_IM[X2] < 4.567 DO SETAL(61000)
Cycles and cycle alarms
For information about cycles and cycle alarms, please see
References:
/PGZ/Programming Manual Cycles
98
Movement"
time variables"
;
Set alarm, when distance (actual value of the axis X1 - actual value of the axis X2)
;
falls short of the critical value 4.567.
Function Manual, 11/2006, 6FC5397-5BP10-2BA0
Synchronized actions