2.9.2

Displaying main run variables

Description
System variables can be monitored for the purpose of monitoring synchronized actions.
Variables, which may be used in this way are listed for selection by the user.
A complete list of individual system variables with ID code W for write access and R for read
access for synchronized actions can be found in:
References:
/PGA1/ Parameter Manual, System Variables
Views
"Views" are provided to allow the user to define the values, which are relevant for a specific
machining situation and to determine how (in lines and columns, with what text) these values
must be displayed. Several views can be arranged in groups and stored in correspondingly
named files.
Managing views
A view defined by the user can be stored under a name of his choice and then called again.
Variables included in a view can still be modified (Edit View).
Displaying main run variable of a view
The values assigned to a view are displayed by calling the corresponding user-defined view.
2.9.3

Logging main run variables

Starting point
To be able to trace events exactly in synchronized actions, it is necessary to monitor the
action status in the interpolation cycle.
Method
The values defined in a log definition are written to a log file of defined size in the specified
cycle. Special functions for displaying the contents of log files are provided.
Synchronized actions
Function Manual, 11/2006, 6FC5397-5BP10-2BA0
2.9 Diagnostics (only with HMI Advanced)
Detailed description
121