3x230 V
Output data according to EN 14 511
Specified heating output (P
1
COP
Specified heating output (P
2
COP
Specified heating output (P
3
COP
Additional power
Output immersion heater
Electrical data
Rated voltage
Max operating current
Driving power circulation pump
Driving power exhaust air fan
Fuse
Enclosure class
Refrigerant circuit
Type of refrigerant
Volume
Cut-out value pressostat HP
Cut-out value pressostat LP
Heating medium circuit
Max pressure in boiler section
Max temperature (flow line)
Ventilation
Min. air flow at exhaust air temperature at least 20 °C
Min. air flow at exhaust air temperature below 20 °C
Sound effect level according to EN 12 102
Sound power level (L
Sound pressure levels
Sound pressure level in the boiler room (L
Pipe connections
Heating medium ext Ø
Hot water ext Ø
Cold water ext Ø
Docking ext Ø
Ventilation Ø
66
Chapter 12 |
Technical data
1
)
H
2
)
H
3
)
H
4
)
W(A)
5
)
P(A)
kW
2.18
3.93
kW
2.03
3.24
kW
1.88
2.74
kW
10.0 (factory setting 6.67)
V
230 V 3N~50 Hz
A
See table page 24
W
15-55
W
25-140
A
See table page 24
IP 21
R290, propane
kg
0.4
MPa/bar
2.45/24.5
MPa/bar
0.15/1.5
MPa/bar
0.25/2.5
°C
70 (factory setting 60)
l/s
28
l/s
31
dB(A)
46.5-48.0
dB(A)
42.5-44.0
mm
22
mm
22
mm
22
mm
22
mm
125