TIP
Complete holiday setting about a day before
your return so that room temperature and hot
water have time to regain usual levels.
TIP
Set the vacation setting in advance and activ-
ate just before departure in order to maintain
the comfort.
Caution
If you choose to switch off hot water produc-
tion during the vacation "periodic increase"
(preventing bacterial growth) are blocked
during this time. "periodic increase" started in
conjunction with the vacation setting being
completed.
Caution
If the exhaust air temperature falls below 16
°C, the compressor is blocked and the electrical
addition is permitted to intervene. When the
compressor is blocked heat is not recovered
from the exhaust air.
Menu 4.9 - advanced
Menu
advanced
the advanced user. This menu has several sub-menus.
Menu 4.9.2 - auto mode setting
stop heating
Setting range: -20 – 40 °C
Default values: 20
stop additional heat
Setting range: -25 – 40 °C
Factory setting: 15
filtering time
Setting range: 0 – 48 h
Default value: 24 h
When the operating mode is set to "auto", the heat
pump selects when start and stop of additional heat
and heat production is permitted, dependent on the
average outdoor temperature.
Select the average outdoor temperatures in this menu.
You can also set the time over which (filtering time)
the average temperature is calculated. If you select 0,
the present outdoor temperature is used.
Caution
It cannot be set "stop additional heat" higher
than "stop heating".
50
Chapter 8 |
Control - Menus
has orange text and is intended for
Menu 4.9.4 - factory setting user
All settings that are available to the user (including
advanced menus) can be reset to default values here.
Caution
After factory setting, personal settings such as
heating curves, ventilation etc must be reset.
Menu 4.9.5 - schedule blocking
The compressor can be scheduled to be blocked for up
to two different time periods here.
When scheduling is active the actual blocking symbol
in the main menu on the heat pump symbol is dis-
played.
Activated
schedule 1
activated
all
mon
tues
we
thur
fri
sat
sun
Day
Time period
Schedule: The period to be changed is selected here.
Activated: Scheduling for the selected period is activ-
ated here. Set times are not affected at deactivation.
Day: Select which day or days of the week the schedule
is to apply to here. To remove the scheduling for a
particular day, the time for that day must be reset by
setting the start time to the same as the stop time. If
the line "all" is used, all days in the period are set for
these times.
Time period: The start and stop time for the selected
day for scheduling are selected here.
Blocking: The desired blocking is selected here.
Conflict: If two settings conflict with each other a red
exclamation mark is displayed.
Blocking the compressor.
Blocking additional heat.
TIP
If you wish to set similar scheduling for every
day of the week start by filling in "all" and then
changing the desired days.
Schedule
schedule blocking 4.9.5
schedule 2
Conflict
Blocking
NIBE™ F370