city price has and the possible savings are larger, but
at the same time there is an increased risk of affecting
comfort.
affect room temperature
Setting range: 1 - 10
Factory setting: 5
affect hot water
Setting range: 1 - 4
Factory setting: 2
This function can only be used if you have an hourly
tariff agreement with your electricity supplier that
supports Smart price adaption.
Smart price adaption moves the heat pump's consump-
tion over 24 hours to periods with the cheapest electri-
city tariff, which gives savings for hourly rate based
electricity contracts. The function is based on hourly
rates for the next 24 hours being retrieved via NIBE
Uplink™ and therefore an internet connection and an
account for NIBE Uplink™ are required.
Untick "activated" to switch off smart price adaption.
Menu 4.2 - op. mode
op. mode
Setting range: auto, manual, add. heat only
Default value: auto
functions
Setting range: compressor, addition, heating
The heat pump operating mode is usually set to "auto".
It is also possible to set the heat pump to "add. heat
only", but only when an addition is used, or "manual"
and select yourself what functions are to be permitted.
Change the operating mode by marking the desired
mode and pressing the OK button. When an operating
mode is selected, it shows what is permitted in the heat
pump (crossed out = not permitted) and selectable al-
ternatives to the right. To select selectable functions
that are permitted or not, mark the function using the
control knob and press the OK button.
Operating mode auto
In this operating mode the heat pump automatically
selects what functions are permitted.
Operating mode manual
In this operating mode you can select what functions
are permitted. You cannot deselect "compressor" in
manual mode.
Operating mode add. heat only
In this operating mode the compressor is not active,
only additional heat is used.
NIBE™ F370
Caution
If you choose mode "add. heat only" the com-
pressor is deselected and there is a higher op-
erating cost.
Functions
"compressor" is that which produces heating and hot
water for the accommodation. If "compressor" is
deselected, a symbol in the main menu on the heat
pump symbol is displayed. You cannot deselect "com-
pressor" in manual mode.
"addition" is what helps the compressor to heat the
accommodation and/or the hot water when it cannot
manage the whole requirement alone.
"heating" means that you get heat in the accommod-
ation. You can deselect the function when you do not
wish to have heating running.
Caution
If you deselect "addition" it may mean that
insufficient hot water and/or heating in the
accommodation is achieved.
Menu 4.3 - my icons
You can select what icons should be visible when the
door to F370 is closed. You can select up to 3 icons. If
you select more, the ones you selected first will disap-
pear. The icons are displayed in the order you selected
them.
Menu 4.4 - time & date
Set time and date, display mode and time zone here.
TIP
Time and date are set automatically if the heat
pump is connected to NIBE Uplink™. To obtain
the correct time, the time zone must be set.
Menu 4.6 - language
Choose the language that you want the information
to be displayed in here.
Menu 4.7 - holiday setting
To reduce energy consumption during a holiday you
can schedule a reduction in heating, ventilation and
hot water temperature. Solar panel cooling can also
be scheduled if the function is connected.
If a room sensor is installed and activated, the desired
room temperature (°C) is set during the time period.
This setting applies to all climate systems with room
sensors.
If a room sensor is not activated, the desired offset of
the heating curve is set. One step is usually enough to
change the room temperature by one degree, but in
some cases several steps may be required. This setting
applies to all climate systems without room sensors.
Vacation scheduling starts at 00:00 on the start date
and stops at 23:59 on the stop date.