Setting the ventilation
Ventilation must be set according to applicable stand-
ards. The setting is made in menu 5.1.5.
Even if ventilation is roughly set at installation it is im-
portant that a ventilation adjustment is ordered and
permitted.
NOTE
Order a ventilation adjustment to complete
the setting.
Available
pressure
Tillgängligt tryck (Pa)
(Pa)
450
400
350
300
250
200
150
100
50
20%
10%
0
0
20
Power output
Effekt
(W)
(watt)
140
120
100
80
60
40
20
10% 20%
0
0
20
32
Chapter 6 |
Commissioning and adjusting
Fan diagram F370
70%
60%
50%
40%
30%
40
60
80
Flow (l/s)
Power direct current fan
90%/100%
80%
70%
60%
50%
40%
30%
40
60
80
100
Luftflöde (l/s)
Commissioning without fan
The heat pump can be run without recovery, as only
an electric boiler, to produce heat and hot water, for
example before the ventilation installation is complete.
Enter menu 4.2 - "op. mode" and select "add. heat only"
Enter menu 5.1.5 - "fan sp. exhaust air" and reduce the
fan speed to 0%.
90%/100%
80%
100
120
Flöde (l/s)
Airflow
(l/s)
120
NOTE
Select operating mode "auto" or "manual"
when the heat pump is to run on recovery
again.