Time period: The start and stop time for the selected
day for scheduling are selected here.
Adjusting: Set the hot water comfort that is to apply
during scheduling here.
Conflict: If two settings conflict with each other a red
exclamation mark is displayed.
TIP
If you wish to set similar scheduling for every
day of the week start by filling in "all" and then
changing the desired days.
TIP
Set the stop time earlier than the start time so
that the period extends beyond midnight.
Scheduling then stops at the set stop time the
day after.
Scheduling always starts on the date that the
start time is set for.
Menu 2.9 - advanced
Menu
advanced
has orange text and is intended for
the advanced user. This menu has several sub-menus.
Menu 2.9.1 - periodic increase
period
Setting range: 1 - 90 days
Default value: 14 days
start time
Setting range: 00:00 - 23:00
Default value: 00:00
To prevent bacterial growth in the water heater, the
compressor and the immersion heater can increase the
hot water temperature for a short time at regular inter-
vals.
The length of time between increases can be selected
here. The time can be set between 1 and 90 days.
Factory setting is 14 days. Tick/untick "activated" to
start/switch off the function.
Menu 2.9.2 - hot water recirc.
operating time
Setting range: 1 - 60 min
Default value: 60 min
downtime
Setting range: 0 - 60 min
Default value: 0 min
Set the hot water circulation for up to three periods
per day here. During the set periods the hot water cir-
culation pump will run according to the settings above.
"operating time" decide how long the hot water circu-
lation pump must run per operating instance.
NIBE™ F370
"downtime" decide how long the hot water circulation
pump must be stationary between operating instances.