Emerson FieldQ Series Product Data Sheet page 19

Table of Contents

Advertisement

Product data sheet
1.604.10 Rev. 0 Page 2 of 9
October 2017
Description:
These FieldQ conventionally wired control modules are the
next step for the integrated concept of valve automation.
Next to the components for feedback switches, also all the
pneumatic control components are located inside one module
housing.
Its compact and robust construction incorporates basic
control and feedback functionality and is suitable for indoor
and outdoor use.
These modules are available with ATEX and IECEx certification
for use in Zone 1, 2, 21 and 22, and additionally FM and CSA
certified for use in Class I, Division 1.
Construction:
The Control Module is mounted at the side of the basic
actuator housing. Inside, wiring terminals are available for
connecting control and feedback signals. Two cable entries
are available.
The pilot valves inside the control module are used to send
the actuator to its open or closed position. One pneumatic
connection is available to feed the control module.
General specifications:
Material housing:
Aluminium alloy
Operating media:
Air or inert gasses, filtered at 50µm
(for QC54 5µm)
Pneumatic entry:
Metric units:
Imperial units: 1/4"NPT
Electrical connections:
Pilot valve(s): 6 pole terminal strip.
Switches:
Cable entries:
Metric units:
Imperial units: 1/2" and 3/4"NPT
Enclosure:
Rated IP66 - NEMA4X
Switch points:
Factory set at 15° before each end of
travel (open and closed position).
Adjustable range:
Between -3° to 15° and +75° to +93°
of the end position.
Finish:
Chromated, polyurethane based
coating.
Temperature range:
Depends on the switches inside
the module and or Hazardous Area
approvals (See section "Position
feedback"
Dimensions:
Metric:
See data sheet BQ1.603.08
Imperial/UNC:
See data sheet BQ1.603.09
DIN 3337:
See data sheet BQ1.603.10
FieldQ
Copyright © Emerson. The information in this document is subject to change without notice. Updated data sheets can be obtained from our website
www.emerson.com/fieldq or from your Emerson Automation Solutions - Actuation Technologies Center:
America's: +1 281 477 4100 Europe: +36 22 53 0950 Asia/Pacific: +65 67 77 8211
Electrical safety requirements:
Use
Altitude
Maximum relative
humidity
Mains supply
fluctuation
Over voltage category
Pollution degree
G1/4"
6 pole terminal strip.
2x M20x1.5
Control module overview
: In- and outdoor.
: Operating full power available up
: 80% for temperatures up to 31°C
: Up to ±10% of nominal voltage
: II
: 2
Terminal
compartment
Lockable
Module cover
Electrical entries:
3/4"NPT
or M20
1/2"NPT
or M20
Switch
Pilot valve
terminals
terminals
FieldQ
to 2000 meter (6000 feet).
(87.8°F) decreasing linearly
to 50% relative humidity at 40°C
(104°F).
(3 when the cover remains closed)
Control Module
Type Label
Option: 1 or 2
speed control
throttles
Pneumatic connections:
1/4"BSP or 1/4"NPT
Option: Additional Local
Manual Control for "Fail in
Last Position"
Option: Local Manual
Control
Non-Intrusive switch
point adjustment

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents