Single-screw extruder
Table of Contents

Advertisement

2.3.5.2 Semi-automatic control pipeline system and its control
The Semi-automatic pipeline system is shown in Fig.2-12
1.Water inlet φ34×3.5 2.Steam to extrusion barrel DN40 3.Steam to jacket DN20 4.Pipeline for
safety valve DN40 5.Main valve for steam DN100 6.Steam to conditioner DN80
7.Water outlet
φ34×3.5
Fig.2-12Semi-automatic pipeline system
The difference between pipeline systems of semi-automatic control and full-automatic control lies in the
part for water addition into the extrusion system. Water pipeline of the semi-automatic pipeline system is
shown in Fig.2-13.
1.Water inlet 2.Water return pipe 3.Pressure gaugeⅠ4.Annular siphon G1/2(copper) 5.Water pressure
reducing valve 6.Water outlet
Fig.2-13 Water pipeline of the semi-automatic pipeline system
Water inlet pipe of the semi-automatic pipeline system is the same as that of the full-automatic
pipeline system equipped with a pressure reducing valve and a water discharge pipe that is connected
directly to the glass-tube flow meter installed on the body of principal machine. In production, water
addition to the conditioner and extrusion barrel was managed by manual control of the shut-off valve
under the glass-tube flow meter. Meanwhile, the flow rate can be indicated by the floater inside the
glass-tube flow meter. See Fig.2-14.