Manual Control System; Part No. 15E523 Manual Control - Graco SaniForce BES Series Instructions-Parts List Manual

Bin evacuation system
Table of Contents

Advertisement

Manual Control System

Manual Control System

Part No. 15E523 Manual Control

See F
. 9.
IG
Ref. Key
Switch/Button Name
A
Seal Inflate On/Off
B
Ram Plate Seal Pressure Gauge
C
Ram Plate Seal Regulator
D
Pump On/Off
E
Pump Pressure Gauge
F
Pump Pressure Regulator
G
Ram Directional Switch
H
Ram Up Pressure Gauge
J
Ram Up Regulator
K
Ram Down Pressure Gauge
L
Ram Down Regulator
F
. 9: Part No. 15E523 Manual Control
IG
16
Operation
Switch to ON to inflate ram plate seal.
Switch to OFF to deflate ram plate seal.
Displays Ram plate seal pressure.
Adjust to raise or lower ram plate seal pressure.
Switch to ON to run the pumps.
Switch to OFF to stop the pumps.
Displays current pump pressure.
Adjust to raise or lower pump inlet air pressure.
Switch to UP to raise the ram plate.
Switch to DOWN to apply ram pressure to the material.
Switch to NEUTRAL to hold the position of the ram plate.
Displays Ram Up operation pressure.
Adjust to raise or lower ram up pressure.
Displays Ram Down operation pressure.
Adjust to raise or lower ram down pressure.
Tee is used on four
pump systems only
B
C
E
F
H
J
K
L
A
D
G
ti22760
311163ZAH

Advertisement

Table of Contents
loading

Table of Contents