5.10 PLATFORM RAIL PADDING
NOTE:
Option with limit switches is shown.
3121655
Limit Switch Operation
OAD00410
NOTE:
Platform Rail Padding provides bumpers to platform rails in order
to prevent damage to the platform as well as to objects it
encounters in the field.
An option with limit switches overrides normal platform function
and movement if any of the switches is engaged by an obstruc-
tion in close proximity to the machine.
When any of the limit switches is engaged, machine functions are
disabled and an alarm sounds (three tones). As long as the obstruc-
tion remains present, the machine cannot be moved.
In order to reset the switches in platform mode:
1. Release the selected function.
2. Press and hold the horn button.
3. Re-engage the selected function in reverse direction.
In order to reset the switches in ground mode:
1. Release the selected function.
2. Re-engage the selected function in reverse direction.
Reversed functions move in creep mode until limit switch is no
longer engaged.
SECTION 5 - ACCESSORIES
5-13