Section 11: Specifications
®
Cavitron™ PROPHY-JET
Air Polishing Prophylaxis System: 100/115 VAC Systems
Mode of Operation:
Continuous operation with intermittent loading:
10 minutes ON / 20 minutes OFF
Electrical Voltage
100V Gen 122J
115V Gen 122
Current
1.1/1.1 amps @ 100v/115v
Frequency
50/60 Hertz
Water Pressure
25-60 psig (172 - 414 kPa)
Air Pressure
65-100 psig (448 - 690 kPa)
Flow Rate
Minimum setting (CCW) 0-15 ml/min
Maximum setting (CW) >55 ml/min
Weight
12 lb. -5,4 kg)
Dimensions
Height:
Width:
Depth:
Handpiece Cable:
Foot Control Cable:
Power Cord:
Water Supply Line:
Air Supply Line:
Cavitron™ PROPHY-JET
®
Air Polishing Prophylaxis System: 200/230 VAC Systems
Mode of Operation:
Continuous operation with intermittent loading:
10 minutes ON / 20 minutes OFF
Electrical Voltage
200V Gen 122D
230V Gen 122U
Current
.7/.6 amps @ 200v/230v
Frequency
50/60 Hertz
Water Pressure
172 - 414 kPa
Air Pressure
448-690 kPa
Flow Rate
Minimum setting (CCW) 0-15 ml/min
Maximum setting (CW) >55 ml/min
Weight
5,4 kg
Dimensions
Height:
Width:
Depth:
Handpiece Cable:
Foot Control Cable:
Power Cord:
Water Supply Line:
Air Supply Line:
Section 12: Classification
Type of protection against electric shock:
Degree of protection against electric shock:
Degree of protection against the harmful
ingress of water:
Mode of operation:
Degree of safety of application in the presence
of a flammable anaesthetic mixture with air or
with oxygen or nitrous oxide:
Equipment not suitable for use in the
presence of flammable
anesthetics or oxygen.
According to medical device directive:
Section 13: Disposal of Unit
• Accordance with local and state laws.
4 in.
7 3/8 in.
9 ½ in.
81 in.
96 in.
84 in.
96 in.
98 in.
10,2 cm
18,7 cm
24,1 cm
2,0 m
2,4 m
2,1 m
2,4 m
2,5 m
Class 1
Type B
Ordinary
Continuous
IIA (rule 9)
OPERATING ENVIRONMENT
Temperature
10 to 25 degrees celsius
Relative Humidity
30 to 75 percent (non-condensing)
TRANSPORT AND STORAGE CONDITIONS
Temperature
0 to 70 degrees celsius
Relative Humidity
10 to 95 percent (non-condensing)
Atmospheric Pressure
500 HPa to 1060 HPa
AC POWER
IPX1 classification of increase of water
TYPE B EQUIPMENT
FOOTSWITCH
Footswitch not for operating theatres
Protection Class - IPXO
Refer to instruction
manual for information
POWER ON
POWER OFF
ENGLISH • 13