2) Voltage Check (with load)
1
1.
Push the load switch to ON (to arrow
direction) direction for less than 5 seconds.
To identify the battery capacity with the
voltage drop (V) value, discharge the fixed
load capacity (120A) for a certain period (5
seconds).
2.
Read the measurement.
7 ~ 9V (Red): Over discharged
Specified
value
9 ~ 11V (Yellow): Charging
11 ~ 13V: Normal
or faulty
required